Specifications
DC DC AC AC/DC
MODEL NUMBER(S)
—
MPT40HD-CM
†
MPT20HD
†
MPT28HD
MPT41HD MPT41HD-CM MPT21HD
—
MPT42HD MPT42HD-CM MPT27HD
—
MPT43HD MPT43HD-CM
— —
OUTPUT
1 NPN (41HD)
1 PNP (42HD)
1 NPN and 1 PNP (43HD)
1 NPN (41HD)
1 PNP (42HD)
1 NPN and 1 PNP (43HD)
Solid state relay (21HD)
Thyristor (27HD)
Thyristor
LOAD CURRENT
250 mA max. (41HD/42D)
100 mA max. (43HD)
250 mA max. (41HD/42D)
100 mA max. (43HD)
500 mA max. (21HD)
100 mA max. (27HD)
100 mA max.
LEAKAGE CURRENT
≤ 10 µA ≤ 10 µA
≤ 400 µA (21HD)
≤ 10 µA (27HD)
≤ 10 µA
INRUSH CURRENT
— —
12 A for 16 ms (21HD/22HD)
250 mA for 8 ms (27HD)
250 mA for 8 ms
(non-repetitive)
VOLTAGE DROP
≤ 1 VDC (42HD/41HD)
≤ 0.6 VDC (43HD)
≤ 1 VDC (42HD/41HD)
≤ 0.6 VDC (43HD)
≤ 1.2 VAC (21HD)
≤ 3 V (27HD)
≤ 5 V (DC operation)
RESPONSE TIME*
≤ 10 µs ≤ 10 µs
≤ 10 ms (21HD)
≤ 2 ms (27HD)
≤ 2 ms
SHORT CIRCUIT AND
OVERLOAD PROTECTION
No (40HD/41HD/42HD)
Yes (43HD)
No (40HD/41HD/42HD)
Yes (43HD)
No No
REVERSE POLARITY PROTECTION
Yes Yes No No
SUPPLY VOLTAGE
10-30 VDC 10-30 VDC 92-132 VAC, 50/60 Hz
10.8-140 VDC
18-140 VAC, 50/60 Hz
CURRENT CONSUMPTION
≤ 25 mA ≤ 25 mA ≤ 70 mA ≤ 70 mA
ELECTRICAL CONNECTION
Quick
disconnect
type V94
Quick
disconnect
type V1
Quick disconnect
type V93 (20HD)
type V95 (21HD/27HD)
Quick
disconnect
type V95
ADDITIONAL DATA
See page 607
*NOTE: Total response time is the sum of the sensor head and base response times.
†
NOTE: Emitter base only.
MINI STYLE BASE