Cut Sheet

Photoelectric MP Series Modular
Photoelectric Sensors
602
Singapore: +65 6779 9091
fa-info@sg.pepperl-fuchs.com
USA: +1 330 486 0001
fa-info@us.pepperl-fuchs.com
Germany: +49 621 776-4411
fa-info@de.pepperl-fuchs.com
Pepperl+Fuchs Group
www.pepperl-fuchs.com
Subject to modifications without notice Copyright Pepperl+Fuchs
PLUG-IN BASE
Specifications
DC AC AC/DC
MODEL NUMBER(S) MPS30HD
MPS10HD
MPS18HD
MPS31HD MPS11HD
MPS32HD MPS12HD
MPS33HD MPS13HD
MPS17HD
OUTPUT
1 NPN (31HD)
1 PNP (32HD)
1 NPN and 1 PNP (33HD)
Solid state relay (11HD/12HD)
Thyristor (17HD)
Thyristor
LOAD CURRENT
250 mA max. (31HD/32D)
100 mA max. (33HD)
5 mA-1 A (11HD/12HD)
100 mA max. (17HD)
100 mA max.
LEAKAGE CURRENT
10 µA
200 µA (11HD)
240 µA (12HD)
10 µA (17HD)
10 µA
INRUSH CURRENT
30 A for 8 ms (11HD/12HD)
250 mA for 8 ms (17HD)
250 mA for 8 ms,
(non-repetitive)
VOLTAGE DROP
1.0 VDC (31HD/32HD)
0.8 VDC (33HD)
1.4 VAC at rated load (11HD/12HD)
3 V at 60 mA (17HD)
5 VDC (DC operation)
RESPONSE TIME*
10 µs
10 ms (11HD/12HD)
2 ms (17HD)
2 ms
SHORT CIRCUIT AND
OVERLOAD PROTECTION
No (30HD/31HD/32HD)
Yes (33HD)
No No
REVERSE POLARITY PROTECTION
Yes No No
SUPPLY VOLTAGE
10-30 VDC
92-132 VAC, 50/60 Hz (10HD/11H/17HD)
198-264 VAC, 50/60 Hz (12HD/13HD)
10.8-140 VDC
18-140 VAC, 50/60 Hz
CURRENT CONSUMPTION
25 mA 70 mA 50 mA
ELECTRICAL CONNECTION
Dependent on
receptacle selection
Dependent on
receptacle selection
Dependent on
receptacle selection
ADDITIONAL DATA
See page 603
*NOTE: Total response time is the sum of the sensor head and base response times.
NOTE: Emitter base only.