Data Sheet

Germany: +49 621 776 1111Pepperl+Fuchs Group
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com
Inductive sensor NCB5-18GM40-N0-10M
3
Release date: 2019-04-25 16:36 Date of issue: 2019-04-25 181109_eng.xml
Equipment protection level Gc (nL)
Standard conformity EN 60079-15:2005 Ignition protection category "n"
Use is restricted to the following stated conditions
Effective internal capacitance C
i
95 nF ; a cable length of 10 m is considered.
Effective internal inductance L
i
100 µH ; a cable length of 10 m is considered.
General The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual.
The data stated in the data sheet are restricted by this operating instruction!
The special conditions must be observed!
The ATEX Directive applies only to the use of apparatus under atmospheric conditions.
If you use the device outside atmospheric conditions, consider that the permissible safety parameters should be
reduced.
Special conditions
for Pi=34 mW, Ii=25 mA, T6
55 °C (131 °F)
for Pi=34 mW, Ii=25 mA, T5
55 °C (131 °F)
for Pi=34 mW, Ii=25 mA, T4-T1
55 °C (131 °F)
for Pi=64 mW, Ii=25 mA, T6
55 °C (131 °F)
for Pi=64 mW, Ii=25 mA, T5
55 °C (131 °F)
for Pi=64 mW, Ii=25 mA, T4-T1
55 °C (131 °F)
for Pi=169 mW, Ii=52 mA, T6
52 °C (125.6 °F)
for Pi=169 mW, Ii=52 mA, T5
52 °C (125.6 °F)
for Pi=169 mW, Ii=52 mA, T4-T1
52 °C (125.6 °F)
for Pi=242 mW, Ii=76 mA, T6
44 °C (111.2 °F)
for Pi=242 mW, Ii=76 mA, T5
44 °C (111.2 °F)
for Pi=242 mW, Ii=76 mA, T4-T1
44 °C (111.2 °F)
Equipment protection level Da
CE marking 0102
ATEX marking ¬ II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label.
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety"
Use is restricted to the following stated conditions
Appropriate type NCB5-18GM...-N0...
Effective internal capacitance C
i
95 nF ; a cable length of 10 m is considered.
Effective internal inductance L
i
100 µH ; a cable length of 10 m is considered.
Maximum permissible ambient temperature T
amb
Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the
surface temperature, and the effective internal reactance values can be found on the EC-type-examination
certificate.
The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of
the two values must be maintained.
Equipment protection level Dc
CE marking 0102
ATEX marking ¬ II 3D IP67 T 109 °C (228.2 °F) X
Standards EN 50281-1-1
Protection via housing
Use is restricted to the following stated conditions
Special conditions
Maximum heating (Temperature rise)
Values can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum
series resistance Rv.
at U
Bmax
=9 V, R
V
=562
9 K
using an amplifier in accordance with EN 60947-
5-6
9 K
Equipment protection level Dc (tc)
CE marking 0102
ATEX marking ¬ II 3D Ex tc IIIC T80°C Dc
The Ex-related marking can also be printed on the enclosed label.
Standards EN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information
provided in the datasheet.
General The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and
control drawings, where applicable (see datasheets), form an integral part of this document. These documents can
be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a
layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the
information provided in the datasheet.
Special conditions
Maximum permissible ambient temperature T
Umax
Values can be obtained from the following list, depending on the max. operating voltage Ub max and the minimum
series resistance Rv.
at U
Bmax
=9 V, R
V
=562
61 °C (141.8 °F)
using an amplifier in accordance with EN 60947-
5-6
61 °C (141.8 °F)