Data Sheet

Germany: +49 621 776 1111Pepperl+Fuchs Group
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com
Inductive sensor NCB5-18GM40-N0-10M
2
Release date: 2019-04-25 16:36 Date of issue: 2019-04-25 181109_eng.xml
Electrical Connection
Equipment protection level Ga
CE marking 0102
ATEX marking ¬ II 1G Ex ia IIC T6T1 Ga The Ex-related marking can also be printed on the enclosed label.
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety"
Use is restricted to the following stated conditions
Appropriate type NCB5-18GM...-N0...
Effective internal capacitance C
i
95 nF ; a cable length of 10 m is considered.
Effective internal inductance L
i
100 µH ; a cable length of 10 m is considered.
Ambient temperature Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the
temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
Note:
Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already
been applied to the temperature table for category 1.
Equipment protection level Gb
CE marking 0102
ATEX marking ¬ II 1G Ex ia IIC T6T1 Ga
The Ex-significant identification is on the enclosed adhesive label
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection "Intrinsic safety"
Use is restricted to the following stated conditions
Appropriate type NCB5-18GM...-N0...
Effective internal capacitance C
i
95 nF ; a cable length of 10 m is considered.
Effective internal inductance L
i
100 µH ; a cable length of 10 m is considered.
Maximum permissible ambient temperature T
amb
Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the
temperature class, and the effective internal reactance values can be found on the EC-type examination certificate.
Equipment protection level Gc (ic)
Certificate PF 13 CERT 2895 X
CE marking
ATEX marking ¬ II 3G Ex ic IIC T6T1 Gc
The Ex-significant identification is on the enclosed adhesive label
Standards EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection category "ic" Use is restricted to the following
stated conditions
Effective internal capacitance C
i
95 nF ; a cable length of 10 m is considered.
Effective internal inductance L
i
100 µH ; A cable length of 10 m is considered.
Special conditions
for Pi=34 mW, Ii=25 mA, T6
55 °C (131 °F)
for Pi=34 mW, Ii=25 mA, T5
55 °C (131 °F)
for Pi=34 mW, Ii=25 mA, T4-T1
55 °C (131 °F)
for Pi=64 mW, Ii=25 mA, T6
55 °C (131 °F)
for Pi=64 mW, Ii=25 mA, T5
55 °C (131 °F)
for Pi=64 mW, Ii=25 mA, T4-T1
55 °C (131 °F)
for Pi=169 mW, Ii=52 mA, T6
52 °C (125.6 °F)
for Pi=169 mW, Ii=52 mA, T5
52 °C (125.6 °F)
for Pi=169 mW, Ii=52 mA, T4-T1
52 °C (125.6 °F)
for Pi=242 mW, Ii=76 mA, T6
44 °C (111.2 °F)
for Pi=242 mW, Ii=76 mA, T5
44 °C (111.2 °F)
for Pi=242 mW, Ii=76 mA, T4-T1
44 °C (111.2 °F)
BN
L+
L-
BU