Inductive sensor NJ5-11-N-G-10M
4
Release date: 2019-05-15 17:04 Date of issue: 2019-05-15 306131_eng.xml
Equipment protection level Gc (ic)
Type of protection intrinsic safety
CE marking
Certificates
ATEX certificate
PF 13 CERT 2895 X
ATEX marking
¬ II 3G Ex ic IIC T6…T1 Gc
Standards
EN 60079-0:2012+A11:2013 , EN 60079-11:2012
Effective internal capacitance C
i
≤ 45 nF
A cable length of 10 m is considered.
Effective internal inductance L
i
≤ 50 µH
A cable length of 10 m is considered.
Maximum permissible ambient temperature T
amb
Also observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at U
i
= 20 V , I
i
= 25 mA , P
i
= 34 mW ,
T6 : 55 °C (131 °F)
T5 : 55 °C (131 °F)
T4 : 55 °C (131 °F)
T3 : 55 °C (131 °F)
T2 : 55 °C (131 °F)
T1 : 55 °C (131 °F)
at U
i
= 20 V , I
i
= 25 mA , P
i
= 64 mW ,
T6 : 55 °C (131 °F)
T5 : 55 °C (131 °F)
T4 : 55 °C (131 °F)
T3 : 55 °C (131 °F)
T2 : 55 °C (131 °F)
T1 : 55 °C (131 °F)
at U
i
= 20 V , I
i
= 52 mA , P
i
= 169 mW ,
T6 : 32 °C (89.6 °F)
T5 : 32 °C (89.6 °F)
T4 : 32 °C (89.6 °F)
T3 : 32 °C (89.6 °F)
T2 : 32 °C (89.6 °F)
T1 : 32 °C (89.6 °F)
at U
i
= 20 V , I
i
= 76 mA , P
i
= 242 mW ,
T6 : 16 °C (60.8 °F)
T5 : 16 °C (60.8 °F)
T4 : 16 °C (60.8 °F)
T3 : 16 °C (60.8 °F)
T2 : 16 °C (60.8 °F)
T1 : 16 °C (60.8 °F)
Equipment protection level Da
Type of protection intrinsic safety
CE marking 0102
Certificates
Appropriate type
NJ 5-11-N...
ATEX certificate
PTB 00 ATEX 2048 X
ATEX marking
¬ II 1D Ex ia IIIC T135°C Da
Standards
EN 60079-0:2012+A11:2013 , EN 60079-11:2012
IECEx certificate
IECEx PTB 11.0037X
IECEx marking
Ex ia IIIC T135°C Da
Standards
IEC 60079-0:2011 , IEC 60079-11:2011
Effective internal capacitance C
i
≤ 45 nF
A cable length of 10 m is considered.
Effective internal inductance L
i
≤ 50 µH
A cable length of 10 m is considered.
Maximum permissible ambient temperature T
amb
Also observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at U
i
= 16 V , I
i
= 25 mA , P
i
= 34 mW : 100 °C (212 °F)
at U
i
= 16 V , I
i
= 25 mA , P
i
= 64 mW : 100 °C (212 °F)
at U
i
= 16 V , I
i
= 52 mA , P
i
= 169 mW : 82 °C (179.6 °F)
at U
i
= 16 V , I
i
= 76 mA , P
i
= 242 mW : 63 °C (145.4 °F)
Equipment protection level Mb
Certificates
Appropriate type
NJ 5-11-N...
IECEx certificate
IECEx PTB 11.0037X
IECEx marking
Ex ia I Mb
Standards
IEC 60079-0:2011 , IEC 60079-11:2011
Effective internal capacitance C
i
≤ 45 nF
A cable length of 10 m is considered.
Effective internal inductance L
i
≤ 50 µH
A cable length of 10 m is considered.
Maximum permissible ambient temperature T
amb
Also observe the maximum permissible ambient temperature stated in the general technical data.
Keep to the lower of the two values.
at U
i
= 16 V , I
i
= 25 mA , P
i
= 34 mW : 100 °C (212 °F)
at U
i
= 16 V , I
i
= 25 mA , P
i
= 64 mW : 100 °C (212 °F)
at U
i
= 16 V , I
i
= 52 mA , P
i
= 169 mW : 82 °C (179.6 °F)
at U
i
= 16 V , I
i
= 76 mA , P
i