Inductive sensor NBN25-30GM50-E2-V1-M1
2
Release date: 2017-07-07 14:17 Date of issue: 2017-07-07 293454-0070_eng.xml
Electrical Connection
Pinout
Installation Hint
1
L+
L-
4
3
1
3
4
2
1 BN
2 WH
3 BU
4 BK
Wire colors in accordance with EN 60947-5-2
(brown)
(white)
(blue)
(black)
Mains-borne interference in accordance with ISO
7637-2:
Pulse 1 2a 2b 3a 3b 4
Severity level III III III III III III
Failure criterion A A C A A C
EN 61000-4-2: CD: 8 kV / AD: 15 kV
Severity level IV IV
EN 61000-4-3: 36 V/m (80...2500 MHz)
Severity level IV
EN 61000-4-4: 2 kV
Severity level III
EN 61000-4-6: 30 V (0.01...80 MHz)
Severity level III
EN 55011: Class A