Datasheet
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49 621 776-0 • USA +1 330 4253555 • Singapore +65 67799091 • Internet http://www.pepperl-fuchs.com
Ultrasonic sensor UB300-18GM40-E5-V1
3
Release date: 2010-10-28 09:40 Date of issue: 2010-10-28 220357_ENG.xml
• Set target to far switching point
• TEACH-IN switching point A1 with -U
B
TEACH-IN switching point, normally-open function
• Set target to near switching point
• TEACH-IN switching point A2 with +U
B
• Cover sensor with hand or remove all objects from sensing range
• TEACH-IN switching point A1 with -U
B
TEACH-IN switching point, normally-closed function
• Set target to near switching point
• TEACH-IN switching point A1 with -U
B
• Cover sensor with hand or remove all objects from sensing range
• TEACH-IN switching point A2 with +U
B
TEACH-IN detection of objects presence
• Cover sensor with hand or remove all objects from sensing range
• TEACH-IN switching point A1 with -U
B
• TEACH-IN switching point A2 with +U
B
Default setting of switching points
A1 = blind range, A2 = nominal distance
LED Displays
Installation conditions
If the sensor is installed at places, where the environment temperature can fall below 0 °C, for the sensors fixation, one of the
mounting flanges BF18, BF18-F or BF 5-30 must be used.
In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing
thread. If a fixation at the front end of the threaded housing is required, plastic nuts with centering ring (accessories) must be
used.
Displays in dependence on operating mode Red LED Yellow LED
TEACH-IN switching point:
Object detected
No object detected
Object uncertain (TEACH-IN invalid)
off
flashes
On
flashes
off
off
Normal operation off Switching state
Fault on Previous state