User Manual
SMF2-FG Series Media Filter
Operating & Maintenance Manual
PEP Filters • 322 Rolling Hill Road • Mooresville, NC 28117 • 800-243-4583 • www.pepfilters.com
704-662-3133 (Outside USA) Page 15 of 16 Fax 704-662-3155
rev. 01/02
Table 5a. Electrical Requirements / Three Phase (60 Hz)
PUMP Motor
HP / KW
Voltage 3φ
60 HZ
Full Load Current (Amps)
1 / 0.75 208, 230, 460, 575 4, 3.6, 1.8, 1.4
2 / 1.5 208, 230, 460, 575 7.5, 6.8, 3.4, 2.7
3 / 2.24 208, 230, 460, 575 10.6, 9.6, 4.8, 3.9
5 / 3.73 208, 230, 460, 575 16.7, 15.2, 7.6, 6.1
Table 5b: Electrical Requirements / Three Phase (50Hz)
HP / KW
Voltage 3φ
50 HZ
Full Load Current (Amps)
1 / 0.75 380, 415 1.7, 1.6
2 / 1.5 380, 415 3.4, 3.1
3 / 2.2 380, 415 5.2, 4.7
Table 6. Media Quantities: SMF-FG
Model
SMF2-FG
Unigran 55 & 85
(50 lb. pails)
Unigran 475 – (for under-drain
support, 50 lb. bags)
20 4 -0-
24 5 -0-
30 8 -0-
36 10 9
42 15 12
48 22 19