Table 5a Electrical Requirements (3φ, 60Hz)
PUMP
HP/KW
Voltage 3φ
60 HZ
Full Load
Current (AMPS)
2 / 1.5 208, 230, 460, 575 7.5, 6.8, 3.4, 2.7
3 / 2.2 208, 230, 460, 575 10.6, 9.6, 4.8, 3.9
5 / 3.7 208, 230, 460, 575 16.7, 15.2, 7.6, 6.1
7.5 /5.6 208, 230, 460, 575 24.2, 22, 11, 9
Table 5b Electrical Requirements (3φ, 50Hz)
PUMP
HP/KW
Voltage 3φ∅
50 HZ
Full Load
Current (AMPS)
2 / 1.5 380, 415 3.4, 3.1
3 / 2.2 380, 415 5.2, 4.7
5 / 3.7 380, 415 8.0, 7.1
Table 6 Media Quantities for HMF2 Filters (non-code vessels)
HMF2 Filtration System
Size / Model
Fill Gravel
1 Pail = .5 ft
3
Unifill 475
Filter Media
(total quantity)
12 1 pail 1 pail
18 2 pails 2 pails
24 3 pails 4 pails
30 6 pails 6 pails
36 9 pails 9 pails
42 14 pails 12 pails
48 20 pails (or 10 bags) 16 pails (or 8 bags)
*Note: Please check your inspection report for exact amount. LOADING: Fill the filter 1/3 ~ 1/2 full
with water before loading the media. Load media in order described in “Media Loading” section of this
manual. Taking care to distribute the lower fill material around the under drain system, filling all
voids.