User Manual
HMF2 Series Filter System
Operating & Maintenance Manual
PEP Filters • 322 Rolling Hill Road • Mooresville, NC 28117 • 800-243-4583 • www.pepfilters.com
14 of 19
Rev. 041204
Table 1 Inspection Chart
PART HMF MODEL
Filter Tank X
Valves & Linkage X
Filter Inter-connection Piping X
Pump Pre-strainer tank & basket X
Pump X
NEMA 4X Box (Auto only) X
Filter Skid X
Pressure gauge, air relief valves, & tees X
Media (shipped Loose) X
Table 2 Connection Sizes
System Water Backwash City Water
Backwash
HMF2
Model
Pump Inlet Filter Outlet Waste Outlet Inlet City Water
HMF Inches/mm
12 2/50.8 1/25.4 1/25.4 1/25.4
18 2/50.8 2/50.8 2/50.8 2/50.8
24 2/50.8 2/50.8 2/50.8 2/50.8
30 2.5/63.5 2/50.8 2/50.8 2/50.8
36 2.5/63.5 3/76.2 3/76.2 3/76.2
42 3/76.2 3/76.2 3/76.2 3/76.2
48 3/76.2 3/76.2 3/76.2 3/76.2
Table 3 Filter Flow Rates
HMF2
Model
Forward Flow
gpm / lps
Minimum Backwash Flow Rate
gpm / lps
Maximum Backwash Flow Rate
gpm/lps
12 16/.96 12.8/.78 16/.96
18 35/2.2 28/1.8 35/2.2
24 63/3.8 47/3.0 63/3.8
30 98/6.2 74/4.6 98/6.2
36 141/4.0 107/6.7 141/4.0
42 192/13.0 144/9.1 192/13.0
48 251/15.8 188/11.9 251/15.8
Table 4 Electrical Requirements (1φ, 60 Hz.)
PUMP HP/KW
Voltage 1φ 60/50HZ
Full Load Current
(Amps)
1/0.75 110, 208, 240 16, 8.8, 8
2/1.5 115, 208, 230 24, 13.2, 12
3/2.25 208, 230 18.7, 17