INTELLIFLO3™ VSF and INTELLIPRO3™ VSF Variable Speed and Flow Pump User's Guide
PrimingParameters
PumpDashboard˃DeviceSettings˃PrimingParameters
All priming settings can be edited and set from this screen. Tap a specic setting on the right-side of the screen to edit.
1- Enabled/Disabled: ENABLED allows the pump to detect whether
or not the system is properly primed for pump startup.
Ifprimeisnotdetectedthepumpwillenteraprimingcycle,
basedonthesettingsbelow.
2− PrimingSpeed: Set the speed the pump will run during a priming
cycle.
3− MaxPrimingDuration: Set the maximum amount of time the
pump will attempt to prime.
If the pump does not achieve prime during this time a priming error
will display and the pump will stop.
4− PrimingRange: Set the sensitivity of pump prime detection.
Lower settings require higher ow to detect a successful prime.
5− PrimingDelay: Set the amount of time the pump remains at
priming speed before transitioning to the run program.
6− LossofPrime: ENABLED allows the pump to detect low-ow or
no-ow situations while running.
If a loss of prime is detected the pump will pause and attempt to
prime, based on the settings above. If priming is successful the
pump will continue programmed operation.
LimitsParameters
PumpDashboard˃DeviceSettings˃LimitsParameters.
Set and edit pump speed, ow and pressure limits. These settings will ensure your pump does not operate
outside of the programmed parameters.
1- Minimum/MaximumSpeed: Set the absolute minimum and maximum
speeds the pump will be allowed to run. Pump run speed will
never run under or over these two settings.
2− Minimum/MaximumFlow: Set the absolute minimum and
maximum ow rate the pump will be allowed. Pump m
3
/h will never
fall under or exceed these two settings.
Note: These minimum and maximum ow rates only apply to
Flow Programs. To apply these settings to Speed Programs as
well, the next setting (Flow Limit - Speed Programs) must be
enabled.
3− FlowLimit(SpeedPrograms): Enable or disable minimum and
maximum ow rate limits for Speed Programs.
4− MaxPressure: Set the absolute maximum system pressure the
pump will be allowed to produce. Pump system pressure will never
exceed this setting.
Note: The maximum pressure setting only applies to Flow
Programs. To apply these settings to Speed Programs as well,
the next setting (Pressure Limit - Speed Programs) must be
enabled.
5− PressureLimit(SpeedPrograms): Enable or disable maximum
system pressure limit for Speed Programs.