User Manual
INTELLIMASTER Variable Speed Controller User Manual
10
VFD CONTROL PARAMETER SETTING
Parameters Input Range Unit Default
Max.Output Frequency 5.0 ~ 70 Hz 50.0
Max. Voltage Frequency 5.0 ~ 70 Hz 50.0
Max. Voltage 50 ~ 250 VAC 240
Mid-Point Frequency 5.0 ~ 70 Hz 25
Mid-Point Voltage 0 ~ 250 VAC 120
Min. Output Frequency 0.10 ~ 20.00 Hz 1.50
Min. Output Voltage 3.0 ~ 200 VAC 15
Acceleration Time 1.0 ~ 120 Sec. 3.0
Deceleration Time 1.0 ~ 120 Sec. 3.0
Stop Mode
0: Ramp to Stop/
1: Coast to Stop
- 1
Motor HP
IDM-1007M [0.5HP] [0.75HP] [1.0HP]
IDM-1015M
[0.5HP] [0.75HP] [1.0HP]
[1.5HP] [2.0HP]
IDM-1022M
[0.5HP] [0.75HP] [1.0HP]
[1.5HP] [2.0HP] [2.5HP]
[3.0HP]
Overload Rate 50 ~ 200 % 150
Overload Time 2.0 ~ 999 Sec 10.0
Over-Voltage Rate 100 ~ 200 % 120
Low-Voltage Rate 70 ~ 90 % 80
Carrier Frequency 3.0 ~ 15.0 KHz 8.0