User's Manual

32
EasyTouch Wireless Control Panel Users and Installation Guide
Solar
To enable a solar heater and set the temperature start and run time settings:
Up/Down buttons: Select Ye s or No to enable solar (1/2). In order to display the
solar selection as a heat source in the Main screen, select Yes .
Right button: Move to the Heat Pump setting.
Up/Down buttons: Select Ye s or No to enable solar as a heat pump. Heat Pump
Control instead of Solar: Select Yes if a heat pump is being used in place of a solar
heating system. If Solar is set to heat pump, Valve A is free for other circuits.
Right button: Select page 2 of 4 (2/4) to access the solar temperature differential
start up and run settings.
Up/Down buttons:
Start: Set the temperature differential to start heating from 3° to 9°. For example, if
“Start” is set to 3°, this ensures that the temperature has to deviate by 3° at least to
the specified set point temperature (in the Heat menu, page 16) before it switches on.
Once the solar comes on it will start converging as it is heating. This ensures that it
will not continually be switching on and off.
Run: Set the temperature differential to stop heating from 2° to 5°. This setting sets
how close to the target set point temperature to switch off solar heat.
Menu/Select: Press this button to save settings and to return to the Settings menu
options. Press the button again to return to the main menu options or press again to
return to the Main screen.
Settings Menu: Delays
Setup which functions (pool/spa, and valves) to assign the delay feature. Delays can be assigned to the
following equipment.
Heater Cool-Down Delay Cancel: Shuts Filter Pump off immediately.
2-Speed Filter Pump five-minute START on HIGH SPEED Delay Cancel: Shifts pump to low
speed.
Automatic Pool Cleaner START Delay: Starts Cleaner Pump immediately, without normal delay in
which the filter pump first runs for 5 minutes.
Automatic Pool Cleaner SOLAR Delay: Allows Cleaner Pump to run even though solar delay has
shut it off for 5 minutes.
Some heaters require a cool-down cycle before being switched off. This can be setup to run the filter pump an
additional ten minutes to dissipate residual heat built up inside the heater combustion chamber. You can also
cancel the delay feature. For information about using the cancel delay feature, refer to “Delay Cancel” on
page 19.
Delays
To assign the delay feature:
Press the Up/Down buttons to select Ye s or No to enable or disable delays for the
pool and spa circuits. Press the Right button to move to the valves setting. Press the
Down buttons to select Ye s or No to enable or disable delays for valves. Press the
Menu/Select button to save and to return to the Settings menu options. Press the
button again to return to the main menu or press again to go to the main screen.
T
Delays
Pool/Spa: No
Valves: No
S
SETTINGS Delays Delays
Getting There
Solar 1/2
Enable: Yes
Heat Pump: No
T
S
S
Solar 2/2
Start: 6°
Run : 4°
T