EasyTouch Wireless Control Panel User’s and Installation Guide
Settings Menu: Circuit Types
Assigning Circuit Types
From the “Circuit Types” menu you can assign special logic to the circuits. For example, when setting up an
automatic pool cleaner pump, you would assign the circuit type MASTER CLEANER. With this "Cleaner"
logic the cleaner pump would force the filter pump on, and the cleaner pump would start after a delay of five
minutes. The cleaner pump would automatically shut off whenever the spa and/or solar is switched on.
Freeze Protection
Freeze protection switches on a circuit if the outside air temperature sensor detects the temperature is getting
close to freezing (below 35° F). The system will switch on all circuits that have been assigned freeze
protection, and runs the circuits for 15 minutes to stop the pipes from freezing. This is especially important if
there is a pool and spa combination. If freeze protection is set to both the spa and pool circuits, the filter pump
switches on and the pool and spa valves alternate every 15 minutes to keep the water moving in both the pool
and spa. This process continues until the freeze condition is over.
Circuit Types
To assign a circuit type and freeze protection:
Up/Down buttons: Choose the circuit that you want to assign the function to. The
generic circuits names are: Spa, Pool, AUX 1 - AUX 7 (EasyTouch 8) and
AUX 1- AUX 3 (EasyTouch 4).
Right button: Move to circuit type setting to select the type of logic needed for your
circuit.
Up/Down buttons: Set the type of circuit to use. This is the circuit that you wish to
assign the function logic to. For a complete list of preset circuit types, see “Preset
Circuit Types,” on page 29.
Right button: Move to Freeze Protection setting.
Up/Down buttons: Select Ye s or No to assign freeze protection to this circuit. If
“Yes” is selected, the circuit will switch on if the air temperature drops to 35° F.
Note: for the POOL circuit the filter pump will have freeze protection. For the
SPA circuit the filter pump will run and the pool/spa valves will switch between
pool and spa at 15 minutes intervals throughout the freeze condition. For the
MASTER CLEANER circuit freeze protection is generally not needed for pool
cleaner pumps since they get water flow from the filter pump. Just make sure
that POOL has freeze protection.
Menu/Select: Press the Menu/Select button to save settings and to return to the
Settings menu options. Press the button again to return to the main menu options or
press again to return to the Main screen.
▼ SETTINGS ▼ CIRCUIT TYPES CIR TYPES
Getting There
▲
Select Types
Crct: Spa
[MASTER SPA ]
Freeze: No
T