200 IMPORTANT Please attach proof of purchase to this manual and file in a safe place. Please visit www.penningtonaquagarden.com for helpful hints, tips, how-to videos and spares Instrauctions español disponible descargar en: www.PenningtonAquagarden.
FOR INDOOR AND OUTDOOR USE IMPORTANT SAFETY INSTRUCTIONS WARNING - TO REDUCE THE RISK OF ELECTRIC SHOCK, USE ONLY ON PORTABLE SELF-CONTAINED FOUNTAINS NO LARGER THAN 5 FEET IN ANY DIMENSION. WARNING - RISK OF ELECTRIC SHOCK - THIS PUMP IS SUPPLIED WITH A GROUNDING CONDUCTOR AND GROUNDING TYPE ATTACHMENT PLUG. TO REDUCE THE RISK OF ELECTRIC SHOCK, BE CERTAIN THAT IT IS CONNECTED ONLY TO PROPERLY GROUNDED, GROUNDING-TYPE RECEPTACLE.
A) B) READ AND FOLLOW ALL SAFETY INSTRUCTIONS. DANGER – TO AVOID POSSIBLE ELECTRIC SHOCK, SPECIAL CARE SHOULD BE TAKEN SINCE WATER IS EMPLOYED AND INTENDED FOR FOUNTAINS, WATERFALLS, AND PONDS, WHICH ARE COMPLETELY SUBMERSED FOR PUMPING WATER AND ARE SUITABLE FOR OUTDOOR USE. FOR EACH OF THE FOLLOWING SITUATIONS, DO NOT ATTEMPT REPAIRS BY YOURSELF; RETURN THE APPLIANCE TO AN AUTHORIZED SERVICE FACILITY FOR SERVICE OR DISCARD THE APPLIANCE.
CONTENTS Getting to know your Inpond 200 Parts Descriptions / spares codes - with exploded diagram 3 3,4 Pump performance / flow chart 5 Specification chart 5 Installation 6 Electrical Installation 7 Installing UVC 7 UVC Electrical Installation 7 Installing Inpond 10 Maintenance and cleaning 13 Cleaning 13 Step by Step guides 14 Routine Maintenance 14 Annual Maintenance 17 Winter storage 17 Troubleshooting 18 Troubleshooting and maximise performance 18 Faults - problem proce
GETTING TO KNOW YOUR INPOND 200 Congratulations on buying a Pennington inpond 5 in 1. Manufactured with advanced technology to create a clean and healthy pond for your fish.
GETTING TO KNOW YOUR INPOND 200 No. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40. 41. 42. 43.
GETTING TO KNOW YOUR INPOND Pump performance / flow chart 5’ 4’ 3’ 2’ 1’ 0’ MODEL 79 gallhr 131 gallhr 143 gallhr 162 gallhr 177 gallhr 192 gallhr 203 gallhr 106 gallhr 238 gallhr 291 gallhr 343 gallhr 372 gallhr 396 gallhr 200 600 300 THIS MODEL TECHNICAL DATA - PUMP TECHNICAL DATA - UV • 120 Volt • 12.
INSTALLATION ELECTRICAL SAFETY INFORMATION: Caution: Household indoor and outdoor use. WARNING - Risk of Electric Shock. Mount the unit at a height greater than 1 foot from the ground surface. Install only to covered Class A GFCI receptacle that has an enclosure that is weatherproof with the attachment plug cap inserted or removed. The power supply must meet the specification of the product. Inpond Pump The electric cord is permanently connected and sealed in the motor body.
UVC INSTALLATION Warning - 1) Always turn off the power before any maintenance to the UVC section 2) Always view the UVC lamp through the viewing window on the UVC Chamber 3) Direct exposure to UVC light can damage your eyes and skin. See part number 5 on getting to know your inpond line drawing on page 3. Caution - Inpond UVC has been fitted with a magnetic safety switch. 1) Do not remove unit with power turned on 2) Do not place near strong magnetic fields.
UVC INSTALLATION 1. Unlock the green UVC electronics cap. 2. Inspect the UVC cap and Quartz sleeve for water leaks. 3. Then unlock the yellow quartz sleeve end cap and unplug the lamp to replace if desired 4. If there are no signs of leakage reverse the procedure ensuring that the quartz sleeve O-ring is in place. See alignment diagram. 5.
UVC ELECTRICAL INSTALLATION Checking the UVC lamp is on In order to check that the UVC lamp is operating: Open the filter unit (see page 14) remove the filter foams and cartridge. Positioned on top of the yellow UVC contact chamber will be a round viewing window, where you should see a faint blue light. This operation may need to be carried out at dusk as UVC lamps emit a dim blue light under noraml operation. Turning the lamp on and off may aid visual identification.
INSTALLATION Locating your Inpond 5 in 1 The Inpond pump and filter should be located on a firm and level base in the pond/water feature in a depth of at least 4”, but no more than 4’10” for the 200 model. Fountain Make sure there is ample cable. Place product in desired location. Using the pipe adjust so the fountain head is above the surface of the pond. Fountain height can now be adjusted, see ‘Adjusting flow control’ diagram below. See ‘’Getting to know your Inpond’’ for parts and descriptions.
INSTALLATION Convenient Installation FOUNTAIN OPTION FEATURE OPTION OR WATER FEATURE FOUNTAIN HOSE INPOND INPOND Note: 1/2” feature hose not provided Inpond 200 INPOND 5 IN 1 RUNS A FOUNTAIN OR FEATURE AND LED SPOTLIGHT Up to 15” fountain extension pipes 20° +/- ball joint adjustment to compensate for uneven pond floor LED spotlight 5w UVC lamp Fully adjustable fountain or feature control. Adjusts fountain height and width.
INSTALLATION Waterfall Installation Important The outlet hose should be smooth bore (not corrugated) pipe installed over as short a distance as possible with no kinks or bends. Connecting a feature hose The recommended hose size is 1/2” for your Inpond. It is not essential but if the fit is not tight a 1/2” jubilee clip can be used to secure the hose. Warming the hose in a bucket of boiling water can aid fitting. Use the shortest possible hose lengths to minimise flow restrictions.
MAINTENANCE & CLEANING IMPORTANT - Failure to carry out routine maintenance leaving the pump under reduced or no flow conditions for long periods will result in a shorter pump life and will invalidate the guarantee. Routine Maintenance Reduced fountain or feature flow indicates that the filter is blocked and needs cleaning. The filter foam may be cleaned vigorously in a bucket of water as required. The polymer wool pad should be replaced if blocked.
MAINTENANCE & CLEANING Routine Maintenance 1. Switch off electricity 2. Remove Inpond from pond (do not use the cables to lift the Inpond) How it works - Flow detail The water flows through the top of the filter cage down through the filter foam and ceramic media then through the UV chamber ready to exit via the pump.
MAINTENANCE & CLEANING Lift the lid from the main filter body After cleaning the filter media replace the filter lid rotating the lid locks in a clockwise direction to secure.
MAINTENANCE & CLEANING Cleaning the impellor The Pennington Inpond 5 in 1 is centrifugal with a magnetic impellor movement driven by a watertight synchronous motor. They require minimum cleaning, only periodic cleaning of the impellor is necessary. Remove the impellor cover and impellor and wash both parts thoroughly. 1. Disconnect the pump from the filter by unscrewing the connecting pipe locking nut counter clockwise 2. Unscrew the impellor cover locking nut counter clockwise 3.
MAINTENANCE & CLEANING Annual maintenance of the filter Check for wear. Once a year you should dismantle your Inpond. Dismantle the filter examining all the parts for wear or damage, replacing any parts showing obvious signs of wear and/or damage (see getting to know your filter for replacement codes and parts descriptions on pages 3 and 4) Annual maintenance of the pump Check for wear. Once a year you should service your pump.
TROUBLESHOOTING Inpond Filter Cloudy/brown water • Check that you have correctly calculated the pond volume, pond depth and if the ponds level of direct sunlight. See page 5 for inpond sizing table. You may require a larger inpond model in the range. Adding shade to the pond by introducing lilies and floating plants to the water surface will reduce pond sludge. Planting the pond with marginal plants will also help create a balance. New ponds may require some time to establish and create a healthy balance.
TROUBLESHOOTING 5. Use the largest diameter, smoothest bore pond hose over the shortest distance and keep hose fittings to a minimum. This removes frictional loss of flow and so increases pump flow rates. Poor Fountain performance • Reduced height. • Jets blocked. Clean flow adjusters and fountain head. Wash under a tap or hose. Lime scale remover should be used to remove lime scale build-up/waste (see diagram) for improved results. DAISY To clean, remove head and rinse.
TROUBLESHOOTING & IMPORTANT UVC light not illuminated • Check all fuses / RCD and electrical connections follow electrical installation Faults - Problem Procedure Before returning your Inpond to your dealer or contacting our Consumer Advice Department, please carry out the following steps. This will solve most problems quickly and easily. 1. Ensure electrical procedures have been followed fully. Check fuses and any cable connectors/switch boxes. 2. (a) Follow routine maintenance procedure fully.
IMPORTANT PUMP & LIGHT This product is guaranteed against defects in material and workmanship for 2 years from date of purchase, under normal usage. This guarantee DOES NOT APPLY in case of improper us, negligence, lack of maintenance or accidental damage either to the pump or the impeller shaft. If the pump fails due to a manufacturing fault within this period it will be either repaired or replaced free of charge.
Aquagarden products by Pennington have been exclusively designed in partnership with Interpet UK a Leading British water garden company Pennington, 1280 Atlanta Hwy, Madison. GA 30650 www.PenningtonAquagarden.