Specification
NSF/ANSI 42
Inuent Challenge
Concentration
Reduction
Requirements
Overall Percentage
Reduction
Chlorine Reduction 2.0
+
/- 10% mg / L 50% 98%
Chloramine Reduction 3.0
+
/- 10% mg / L < 0.5 mg / L 95%
Patrciulate Class 1
Reduction
at least 10,000 particles / mL 85% > 99.9%
NSF/ANSI 53
Inuent Challenge
Concentration
Reduction
Requirements
Overall Percentage
Reduction
Cyst, Live Cryptosporidium &
Giardia
min 50,000 L 99.95% > 99.99%
Mercury Reduction pH 6.5 0.006
+
/- 10% mg / L < 2 ug / L 96.50%
Mercury Reduction pH 8.5 0.006
+
/- 10% mg / L < 2 ug / L 96.80%
Lead Reduction pH 6.5 0.015
+
/- 10% mg / L < 10 ug / L > 99.4%
Lead Reduction pH 8.5 0.015
+
/- 10% mg / L < 10 ug / L > 99.3%
VOC
(Chloroform as Surrogate)
300
+
/- 30% ug / L 95% 99.80%
Organic Chemicals Included by Surrogate Testing
Chemical
Drinking Water
Regulatory Level 1
(MCL / MAC) mg / L
Inuent Challenge Con
-
centration mg / L
Chemical
Reduction Percent
Alachor 0.002 0.050 > 98%
Atrazine 0.003 0.100 > 97%
Benzene 0.005 0.081 > 99%
Carbofuran 0.04 0.190 > 99%
Carbon Tetrachloride 0.005 0.078 98%
Chlorobenzene 0.1 0.077 > 99
Chloropicrin ~ 0.015 99
Substance
Individual Inuent
Sample Point Limits
ug / L
Maximum Efuent Con-
centration ug / L
Average Percent
Reduction
PFOA / PFOS 1.5
+
/- 10% ug / L 0.07 98%
Statements:
Testing was performed under standard laboratory conditions, actual performance may vary. Filter usage must comply with all state and local laws. Filter is
only to be used with cold water. Systems certied for cyst reduction may be used on disinfected waters that may contain lterable cysts. All contaminants
reduced by this lter are listed. Not all contaminants listed may be present in your water. Filter does not remove all contaminants that may be present in tap
water. See owner’s manual for general installation conditions and needs as well as manufacturer’s limited warranty.
Do not use with water that is microbiologically unsafe or of unknown water quality without adequate disinfection before or after the system.
Performance Data Sheet
Pelican PDF-450 Series Premium Countertop Filter
RSF: 0.5 GPM Maximum Temperature: 100˚F
Capacity: 6 Months or 450 Gallons Maximum Temperature: 40˚F
Maximum Pressure: 80 PSI Replacement Model #: PDF-RF
Minimum Pressure: 20 PSI
2, 4-D 0.07 0.110 98%
Dibromochloropropane (DBCP) 0.00002 0.052 > 99%
O-Dichlorobenzene 0.6 0.080 > 99%
P-Dichlorobenzene 0.075 0.040 > 98%
1.2-Dichloroethane 0.005 0.088 95%
1.2-Dichloroethylene 0.007 0.083 0.99%
Cis-1,2-Dichloroethylene 0.07 0.170 > 99%
Trans-1,2-Dichloroethylene 0.1 0.086 > 99%
1.2-Dichloropropane 0.005 0.080 > 99%
Cis-1,2-Dichloropropylene ~ 0.079 > 99%
Dinoseb 0.007 0.170 99%
Endrin 0.002 0.053 99%
Ethylbenzene 0.7 0.088 > 99%
Ethylene Dibromide (EDB) 0.00005 0.044 > 99%
Haloacetonitriles (HAN):
Bromochloroacetonitrile
Dibromoacetonitrile
Dichloroacetonitrile
Trichloroacetonitrile
~
0.022
0.024
0.0096
0.015
98%
98%
98%
98%
Haloketones (HK):
1,1-Dichloro-2-propanone
1,1,1-Trichloro-2-propanone
~ 0.0072
0.0082
99%
96%
Heptachlor (H-34, Heptox) 0.0004 0.025 > 99%
Heptachlor Epoxide 0.0002 0.0107 98%
Hexachlorobutadiene ~ 0.044 > 98%
Hexachlorocyclopentadiene 0.05 0.060 > 99%
Lindane 0.0002 0.055 > 99%
Methoxychlor 0.04 0.050 > 99%
Pantachlorophenol 0.001 0.096 > 99%
Simazine 0.004 0.120 > 97%
Styrene 0.1 0.150 > 99%
1,1,2,2-Tetrachloroethane ~ 0.081 > 99%
Tetrachloroethylene 0.005 0.081 > 99%
Toluene 1 0.078 > 99%
2,4,5-TP (silvex) 0.05 0.270 99%
Tribromoacetic Acid ~ 0.042 > 98%
1,2,4-Trichlorobenzene 0.07 0.16 > 99%
1,1,1-Trichloroethane 0.2 0.084 95%
1,1,2-Trichloroethane 0.005 0.15 > 99%
Trichloroethylene 0.005 0.18 > 99%
Trihalomethanes (includes):
Chloroform (surrogate chemical)
Bromodichloromethane
Chlorodibromomethane
0.080 0.3 95%
Xylenes (total) 10 0.07 > 99%
For more information visit: PelicanWater.com or call 877-842-1635
3060 Performance Circle, Suite 2 | Deland, Florida | 32724
This system has been tested and certied by
NSF International against NSF/ANSI Stan-
dard 42 for the aesthetic reduction of chlorine
taste and odor, chloramine and Particulate
class I, NSF/ANSI Standard 53 for the reduc-
tion of Cysts, Mercury, Lead and VOC’s and
IAPMO R&T certied to NSF/ANSI Standard
P473 for PFOAs & PFOS.