Certificate

TRAC12ATEX0018X, 2012-11-23 Page 2 of 5
13
SCHEDULE TO EC TYPE EXAMINATION CERTIFICATE
14
TRAC12ATEX0018X
15
General description of equipment or protective system included within the scope of this certificate
The type 3715Z0 flashlight is powered by 4 x AA alkaline primary cells. The flashlight light source consists of
an LED array that is arranged to give differing light outputs. The light output is controlled via an electronic
circuit, which is mounted within the flashlight body. The flashlight comprises of a main enclosure, a
removable battery tray and lens assembly. There is a spring-actuated clip at the rear of the flashlight main
enclosure.
A list of controlled Manufacturer’s Documents is given in Appendix A to this schedule.
16
Test report No.:
TRA-009590-33-00A.
17
“Special Conditions of Safe Use” for Ex Equipment, if any:
1. The following cell types are permitted: Energiser E91, Philips LR6 and Panasonic LR6.
2. Replace all cells at the same time.
3. Do not mix cell brands.
4. Cells not to be replaced in the hazardous area.
18
Essential health and safety requirements
Covered by application of the standards listed in section 9 of this certificate and the assessment conducted
in the test report listed in section 16 of this certificate.
19
Additional information
“Routine tests”, if any:
None.
“Special conditions for manufacture”, if any:
None.
Other information, if any:
None.
Photographs