26 C4687M-C (7/13)
Legacy Endura Components
• WS5000/WS5060/WS5070: There are no compatibility restrictions when the SM5200 is used as a replacement for the SM5000. You must
upgrade to the WS5200/WS5070 to utilize the SM5200’s remote access capabilities.
• GW5000/NET5301TC: No compatibility restrictions. The GW5000 and NET5301TC can continue to be used for their respective functions
independently of the SM5200’s remote access capabilities.
• VCD500x: User passwords must be alphanumeric unless a USB keyboard is used to log on.
• NET5301R: No compatibility restrictions
• NVR51xx/SEB51xx: No compatibility restrictions. Footage on NVR51xx units cannot be queried for remote search, playback, or export
from the SM5200.
• DVR53xx: No compatibility restrictions. Footage on DVR53xx cannot be queried for search, playback, or export from the SM5200.
• DVR51xx: No compatibility restrictions in Endura Enabled
™
environments. Footage on Endura Enabled DVR51xx units cannot be queried for
search, playback, or export from the SM5200.
FRONT PANEL INDICATORS/FUNCTIONS
Buttons Power
Indicators
Power Blue
Unit Status Green, amber, red
Primary Network Green, amber, red
Secondary Network Green, amber, red
Software Status Green, amber, red
Drive Status (6X) Green, amber, red
POWER
Power Input 100 to 240 VAC, 50/60 Hz, autoranging
Power Supply Internal
Power Consumption Operating Maximum
110 VAC, 60 Hz 223.0 W, 2.03 A, 761.4 BTU/H
115 VAC, 60 Hz 215.5 W, 1.87 A, 735.7 BTU/H
220 VAC, 60 Hz 204.1 W, 0.93 A, 696.8 BTU/H
Power Cords 1 power cord based on country designation
NOTE: Units shipped to China do not contain power cords. A CCC approved power cord must be used to
power this equipment when used in China.
ENVIRONMENTAL
Operating Temperature 10° to 35°C (50° to 95°F)
Storage Temperature –40° to 65°C (–40° to 149°F)
Operating Humidity 20 to 80%, noncondensing
Maximum Humidity Gradient 10% per hour
Operating Altitude –15 to 3,048 m (–50 to 10,000 ft)
Operating Vibration 0.25 G at 3 Hz to 200 Hz at a sweep rate of 0.5 octave/minute
NOTE: The temperature at the unit air intake can be significantly higher than room temperature. Temperature is affected by rack configuration,
floor layout, air conditioning strategy, and other issues. To prevent performance failure and unit damage, make sure the temperature at the unit is
continuously within the operating temperature range.
PHYSICAL
Dimensions 50.8 x 43.4 x 8.9 cm
(20" D x 17.1" W x 3.5" H)
Mounting Rack or desktop (feet)
Weight Unit
SM5200-03 17.1 kg (37.8 lb)