Spec Sheet

TECHNICAL SPECIFICATIONS
MECHANICAL (Dome Drive Only)
Pan Movement 360° continuous pan rotation
Vertical Tilt Unobstructed +2° to –92°
Manual Pan/Tilt Speeds
Pan 0.1° to 80°/sec manual operation,
150°/sec Turbo
Tilt 0.1° to 40°/sec manual operation
Preset Speeds
Pan 400°/sec
Tilt 200°/sec
For variable-speed operation an appropriate
controller is required (with nonvariable speed
control, Spectra IV pan/tilt speed is 20°/sec)
ELECTRICAL
Input Voltage 18 to 32 VAC; 24 VAC nominal
22 to 27 VDC; 24 VDC nominal
Input Power
24 VAC 23 VA nominal (without heater);
73 VA nominal (with heater)
24 VDC 0.7 A nominal (without heater);
3 A nominal (with heater)
Fuse 1.25 A
CERTIFICATIONS/RATINGS/PATENTS
CE, Class B
FCC, Class B
UL/cUL Listed
•C-Tick
S Mark for Argentina
Meets NEMA Type 4X, IP66 when installed properly (BB4-F-E, BB4-PB,
BB4-PG, and BB4-PG-E)
Meets NEMA Type 1, IP40 (BB4-SMW, BB4-SMB, and BB4-F)
U.S. Patents 5,931,432; 6,793,415 B2; 6,802,656 B2; 6,821,222 B2;
7,161,615 B2
GENERAL
Construction
Back Box
Surface Mount Plastic
In-Ceiling Aluminum
Pendant Aluminum
Dome Drive Aluminum, thermo plastic
Bubble Acrylic
Light Attenuation
Smoked f/0.5 light loss
Clear Zero light loss
Chrome f/2.0 light loss
Gold f/2.0 light loss
Cable Entry (Back Box)
In-Ceiling and
Surface Mount 0.75-inch conduit fitting
Pendant Through 1.5-inch NPT pendant mount
Weight (approximate) Unit
Shipping
Back Box
Surface Mount 0.32 kg (0.7 lb) 0.90 kg (2 lb)
In-Ceiling 0.68 kg (1.5 lb) 0.90 kg (2 lb)
Environmental
In-Ceiling 0.95 kg (2.1 lb) 1.36 kg (3 lb)
Standard Pendant 1.09 kg (2.4 lb) 1.81 kg (4 lb)
Environmental Pendant 1.59 kg (3.5 lb) 2.27 kg (5 lb)
Dome Drive 1.48 kg (3.3 lb) 2.27 kg (5 lb)
Lower Dome
Surface Mount 0.18 kg (0.4 lb) 0.45 kg (1 lb)
In-Ceiling 0.09 kg (0.2 lb) 0.45 kg (1 lb)
Pendant and
Environmental
In-Ceiling 0.27 kg (0.6 lb) 0.90 kg (2 lb)
Environment
Surface Mount Indoor
In-Ceiling Indoor
Environmental In-Ceiling Outdoor
Pendant, Standard
and Environmental Indoor/outdoor
Operating Temperature
Surface Mount and
Indoor In-Ceiling 0° to 50°C (32° to 122°F)
Standard Pendant (Assumes no wind chill factor)
Maximum 45°C (113°F) absolute maximum;
35°C (95°F) sustained maximum
Minimum –4°C (25°F) sustained minimum
Environmental
In-Ceiling and
Environmental Pendant (Assumes no wind chill factor)
Maximum 60°C (140°F) absolute maximum;
50°C (122°F) sustained maximum
Minimum –51°C (–60°F) absolute minimum; prevents
icing at sustained minimum of –45°C (–50°F);
de-ices 2.5 mm (0.1 in.) within 3 hours after
power-up
TS2 –34° to 74°C (–29.2° to 165°F)
Per NEMA TS2, para. 2.1.5.1, using fig. 2.1 test profile
Effective Projected
Area (EPA) 20.5 square inches (without mount)
47 square inches (with IWM Series mount)