Instructions

65
FIGURE 2-53: RELAY OPEN/CLOSE HANDLER SETTINGS
Relay Open/Close Handler
1. Check any or all of the Alarm, Motion 1 through 4, Sabotage Detection, Audio Detection, Object Counting,
Adaptive Motion, Object Removal, as well as Directional Motion options from the Enabled section to activate
relay handler when any of the selected events occur.
2. Select Normally Open or Normally Close from the drop-down menu of Polarity for the relay handler.
3. Move the On Time slider to set the amount of time that the relay will remain open. The time range is 0.1 to 200
seconds; the default setting is 0.1.
4. Move the Off Time slider to set the amount of time that the relay will remain closed. The time range is 0.1 to 200
seconds; the default setting is 0.1.
5. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without
saving it.
NOTE: The Relay Open/Close Handler is available in Alarm equipped models only.