Operation Manual
Table Of Contents
- Important Notices
- Accessing the Camera
- Accessing the Live Video Page
- System Menu
- Using the Network & Security Menu
- Using the Imaging Menu
- Configuring Exposure Settings
- Configuring Focus Settings
- Setting White Balance
- Using Window Blanking
- Configuring Options in the PTZ Menu
- Using A/V Streams Menu
- Events
- Configuring Sources
- Configuring Handlers
- Configuring an Event Handler: Send Email
- Configuring an Event Handler: Upload JPEG to FTP Server
- Configuring an Event Handler: Write JPEG to SD Card
- Configuring an Event Handler: Run Pattern
- Configuring an Event Handler: Go to Preset
- Configuring an Event Handler: Run Tour
- Configuring an Event Handler: Run Scan
- Configuring an Event Handler: Open/Close Relay
- Configuring an Event Handler: Display Overlay
- Configuring an Event Handler: Play Audio
- Configuring an Event Handler: Write Recording to SD Card
- Configuring an Event Handler: Upload Recording to FTP Server
- Deleting an Event Handler
- Analytic Configuration
- Event Stream
- Contacting Pelco for Troubleshooting
Spectra Enhanced 7 Operations Manual, PTZDome Cameras
C6653M-B | 06/20
38
6. (Optional) If available, select the source(s)that you want to trigger this event handler.Sources are
configured from the Events tab Sources page.
7. Click Save.
Configuring an Event Handler: Run Tour
You must define a Preset Tour before you can create a Run Tour event handler. Preset tours are configured
from the Imaging tab Preset Tours page.
1. Click New Handler or select the handler you want to reconfigure.
2. Provide a name, between 2 and 23 alphanumeric characters, for the event handler in the Name box.
3. Select the Run Tour handler type.
4. Select a tour from the Tour drop-down menu.
5. (Optional) Set time filters to determine the days and times during which the handler will be active. If
you do not select any filters, the handler will remain active at all times. All time values must be
formatted in 24-hour notation.
6. (Optional) If available, select the source(s) that you want to trigger this event handler.Sources are
configured from the Events tab Sources page.
7. Click Save.
Configuring an Event Handler: Run Scan
This event handler runs a preset scan when an event source is triggered. You must define a Scan before
you can create a Run Scan event handler. Scans are configured from the Imaging tab Scans page.
1. Click New Handler or select the handler you want to reconfigure.
2. Provide a name, between 2 and 23 alphanumeric characters, for the event handler in the Name box.
3. Select the Run Scan handler type.
4. Select the scan from the pull-down menu.
5. (Optional) Set time filters to determine the days and times during which the handler will be active. If
you do not select any filters, the handler will remain active at all times. All time values must be
formatted in 24-hour notation.
6. (Optional) Select one or more sources that you want to trigger this event handler.Sources are
configured from the Events tab Sources page.
7. Click Save.
Configuring an Event Handler: Open/Close Relay
The Open/Close handler opens or closes a relay when a source event occurs.
1. Click New Handler or select the handler you want to reconfigure.
2. Provide a name, between 2 and 23 alphanumeric characters, for the event handler in the Name box.
3. Select the Open/Close Relay handler type.
4. Select the individual relay you want to trigger when an event occurs from the Relay drop-down
menu.
5. Select the Relay Mode: Pulse or Trigger.
6. Use the On Time controls to set the amount of time the relay will remain open, up to 200 seconds.
7. Use the Off Time controls to set the amount of time the relay will remain closed, up to 200 seconds.