® PT506-24DT Pan/Tilt Lens Control PT506-24A Auto/Random Scan Control Installation/ Operation Manual C580M Rev D (9/97) Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 • USA • www.pelco.
CONTENTS Section Page 1.0 GENERAL .................................................................................................. 1 1.1 IMPORTANT SAFEGUARDS AND WARNINGS ............................... 1 2.0 DESCRIPTION .......................................................................................... 2 2.1 MODELS ............................................................................................ 2 2.2 OPTIONS ............................................................................
LIST OF ILLUSTRATIONS Figure 1 2 3 4 5 6 Page PT506-24DT Basic System Configuration ......................................... 3 PT506-24DT Configured with PT506-24A ......................................... 4 PT506-24DT Configured with a Relay Box ........................................ 4 Connector Assembly .......................................................................... 5 PT506-24DT Schematics (Sheet 1 of 5) ............................................ 9 PT506-24DT Schematics (Sheet 2 of 5) ..
(This page intentionally left blank.
1.0 GENERAL 1.1 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6 or 6P enclosure, it is designed for Indoor use only and it must not be installed where exposed to rain and moisture. 3. Only use replacement parts recommended by Pelco. 4.
2.0 DESCRIPTION The PT506-24DT is a pan/tilt and lens control designed to remotely operate 24 VAC pan/tilts and all Pelco motorized zoom lenses. This unit can control up to six (6) different locations, all of which can be selected by pressing the corresponding illuminated push-button switch. The pan/tilt movement is controlled by an eight position joystick. The lens functions and speed are controlled by three momentary paddle switches and a rotary knob.
3.0 INSTALLATION Figure 1 shows a typical rear panel installation of the PT506-24DT controller. The distance from the controller is limited by the wire size and pan/tilt used. (See Section 3.1 Recommended Cable Distances.) Figure 2 shows a typical rear panel installation of the PT506-24A to the PT506-24DT. Figure 3 shows a typical system using a relay box to extend the pan/tilt control range and operate a 120 VAC pan/tilt. 3.
Figure 2. PT506-24DT Configured with PT506-24A Figure 3.
3.2 CONNECTOR ASSEMBLY Assemble the connector parts according to the instructions below. Detail B, below, reflects the pin arrangement specific to all PT506-24DT Pan/Tilt and Lens Control and the PT506-24A Auto/Random Scan Control. Refer to Figure 4 during assembly. For best results use an AMP style crimper when making the wire to pin connection. The instructions that follow apply to all AMP style connectors regardless of pin size or pin number. 1" 1.
4.0 OPERATION The PT506-24DT will not allow control of any of the six pan/tilt stations until one is selected by pressing the desired station on the latching selection switches. Once a selection has been made, the switch will illuminate and all control functions will be available only to that particular station. It is considered that all pan/tilt and lens control functions are self-explanatory. Refer to Section 4.1, OPERATIONAL TEST– PT506-24DT, for details of each control function.
4.2 OPERATIONAL TEST — PT506-24A The PT506-24A will add two modes of automatic pan operation to the PT506-24DT. Once the PT506-24A is interconnected as shown in Figure 2, apply power to the units. When the corresponding paddle switch to the station selected is in the down or middle position, manual control of the pan functions can be obtained. All units power-up in the “manual” mode. Once the switch is momentarily pressed “UP”, the selected station goes into random scan mode.
5.0 MAINTENANCE Under normal operating conditions and usage, maintenance of this equipment is not necessary. However, if maintenance is required, repairs should be performed by a qualified service technician or equipment should be returned to the factory for repair. NOTE: Pelco offers a 24-hour, seven-day-a week Technical Assistance Program (TAP) designed to assist any customer with a technical problem involving Pelco equipment whether it’s the weekend or late at night.
6.0 SCHEMATICS If necessary, refer to the following schematics for troubleshooting or repair Figure 5.
Figure 5.
Figure 5.
Figure 5.
Figure 5.
7.0 SPECIFICATIONS ELECTRICAL PT506-24DT Input Voltage: 120 VAC, 50/60 Hz (230 VAC optional) Output Voltage: 24 VAC, 60 Hz pan/tilt supply 0 to ±9 VDC lens supply Power Requirement: 1.65 amps (190 vA) Cable Requirements: 11 conductors (Pan/tilt 5 + ground; Lens 4 + ground) Fuse Protection: 2 AG type 1ASB Power Cord: 3-wire grounded #18 Awg Connectors: AMP CPC type (mate supplied) Replacement Lamps: Station Select Switch replacement lamp #LAP72524 PT506-24A Power Requirements: 1.
GENERAL Enclosure Construction Panel: Aluminum Cover: Steel, textured black enamel Chassis: Steel, galvanized Temperature Range: 32° to 120°F (0° to 50°C) Size: See Figure 6 Weight PT506-24DT PT506-24A 13 lbs 6 oz (6 kg) 18 lbs (8.1 kg) Shipping Weight PT506-24DT PT506-24A 14 lbs 6 oz (6.5 kg) 19 lbs (8.5 kg) Rating: NEMA 1 (Design and product specifications subject to change without notice.
8.0 WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. • Three years on Genex® Series products (multiplexers, server, and keyboard).