INSTALLATION/OPERATION WCS1-4 Environmental Power Supply C561M-H (3/08)
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Installation should be done only by qualified service personnel and conform to all local codes. 6. Use only installation methods and materials capable of supporting four times the maximum specified load. 7. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 8.
Description The WCS1-4 is a single power supply designed for indoor or outdoor applications and is ideal for use with cameras, domes, and integrated positioning systems such as Spectra® and Esprit®. The WCS1-4 power supply has one fused output and is capable of handling up to 4 amps (100 VA) of total load. The unit features selectable 100/120/240 VAC input power, selectable 24/26/28 VAC output power, and a stainless steel link-lock latch that can be secured with padlock (padlock not provided).
FUSE INSTALLATION The WCS1-4 power supply is shipped from the factory with a 1.6 A fuse installed for 100/120 VAC input power. To use input power of 240 VAC, change the 1.6 A fuse to a 500 mA fuse (supplied). To change the fuse remove the lid to the fuse holder (refer to Figure 4) located inside the power supply and then install the new fuse. Store extra fuses (supplied) in the spare fuse holders. INPUT POWER WIRING WARNING: The WCS1-4 does not have an on/off switch.
OUTPUT WIRING To install the output wiring to the camera, dome, or positioning system, refer to Figure 4 and do the following: 1. Refer to Table A and determine the output connection needed for your camera, dome, or positioning system. Refer to Figure 4, for the proper connector strip connections. 2.
CABLE CONNECTIONS AND REQUIREMENTS The following are the recommended maximum distances to wire the WCS1-4 to a Spectra or Esprit positioning system. To determine the correct voltage tap: 1. Pick the unit type. 2. Find the wire gauge used (22 gauge is not recommended). Determine which secondary output tap (A, B, or C) is appropriate for the distance between the dome or positioning system and the WCS1-4. Distance is in feet (meters). Table A. Maximum Wiring Distance From Transformer to Load 20 AWG (0.
Specifications ELECTRICAL Input Voltage Output Voltage/Power Fusing Spare Fuse Holder Required Input Current Selectable 100, 120, 240 VAC, 50/60 Hz through the Primary Line Input connector strip Selectable 24 VAC (Tap A), 26 VAC (Tap B), or 28 VAC (Tap C) at 100 VA through the Secondary Output Tap’s connector strip 1 fuse. Select from one of the following supplied fuses: 3, 1.
7.32 (18.8) 7.65 (19.4) 6.63 (16.8) 6.71 (17.0) 4.50 (11.4) 4.01 (10.3) 6.50 (16.5) NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC. This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • • • • • • • • • • • • • • Five years on fiber optic products and TW3000 Series unshielded twisted pair (UTP) transmission products. Three years on Spectra® IV products. Three years on Genex® Series products (multiplexers, server, and keyboard).
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.