Installation Manual

Installation
16
|
Installation
SYSTEM ORGANIZATION
MOUNTING IN A RACK
The NET5500 Series encoder mounts into an industry-standard 48 cm (19-inch) equipment rack. The NET5500 Series encoder
occupies 1 RU (4.45 cm or 1.75 inches) of vertical rack space. The hardware necessary to mount the NET5500 Series rack encoder
into a rack is supplied with the unit.
The rack must meet the following requirements
Rack standard : 48 cm (19 inches), EIA-310-D compliant (rear column required)
Rack column depth : 50.8 to 76.2 cm (20 to 30 inches)
Column mounting hole provisions : 10-32 UNF-2B threaded holes or square window holes on front and rear columns.
Door systems (optional) : Front doors must have at least 5.1 cm (2 inches) between the NET5500 Series encoder front bezel and the
inside of the door.
Rear doors may be used only on rack columns that more than 66 cm (26 inches) deep.
J
Make sure the NET5500 Series encoder is level.
J
Slots and openings in the cabinet provide ventilation to prevent the unit from overheating. Do not block these openings.