® SHIFT MO 1 N 2 F1 SE QU ACK 4 3 EN CE PREV F2 NEXT 5 7 F3 HO 6 LD F4 PATT ER 8 CAM N 9 0 F5 PRES ET CLEA MA CR O PG M R KBD3 MADE IN 00 USA. KBD300 Universal Keyboard Installation/ Operation Manual C527M (11/97) Pelco • 300 W. Pontiac Way, Clovis • CA 93612-5699 USA • Pelco Online @ http://www.pelco.
CONTENTS Section Page 1.0 GENERAL .................................................................................................. 1 1.1 IMPORTANT SAFEGUARDS AND WARNINGS ............................... 1 2.0 DESCRIPTION .......................................................................................... 2 3.0 INSTALLATION .......................................................................................... 4 3.1 WALL JACK WIRING ...............................................................
1.0 GENERAL 1.1 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P enclosure, it is designed for Indoor use only and it must not be installed where exposed to rain and moisture. 3. Only use replacement parts recommended by Pelco. 4.
2.0 DESCRIPTION The KBD300 keyboard provides complete programming and operational control of the CM6700 Matrix Switcher. This keyboard features a three axis joystick that includes a twisting, return-to-center head for full control of variable speed pan, tilt and zoom fuctions.
2 3 4 5 6 1 7 SHIFT F1 17 F2 F3 F4 F5 SEQUENCE MON ACK PREV 1 2 3 4 5 6 7 8 9 CLEAR 0 CAM NEXT HOLD PATTERN PRESET NEAR FAR OPEN CLOSE MACRO PGM * The turbo pan feature may be disabled. Place switch 4 on the rear panel DIP switch block in the off position. See Figure 4. 8 16 9 15 10 KBD300 MADE IN USA. 12 * 14 11 13 1. DIGIT DISPLAY LED Displays monitor number in Run mode and P in program mode. 2. SHIFT KEY Press to activate Multiplexer Mode. 3.
3.0 INSTALLATION NOTE: Refer to the CM6700 Installation/Operation Manual (C523M-A) for detailed operating instructions. Communication to the CM6700 keyboards is RS-485. Wall jack, modular data cable, and 12 VAC transformer (all supplied) combine to provide a local, single cable plugin connection to the keyboard. A double-sided sticky pad, to secure the wall jack to a suitable surface, is also supplied. All cabling between wall jacks is user supplied.
3.1 WALL JACK WIRING IMPORTANT: Wall jacks must be wired in a daisy-chain configuration. 1. Determine the location of all keyboards. 2. Run wall jack interconnect cable (user supplied) from the SCU to the closest keyboard location. Then to the next nearest location, and the next, etc. Wall jacks must be within 6 feet (1.8 m) of the nearest suitable electrical outlet. Do not mount the wall jack at this time. 3. Make cable connections between wall jacks according to Figure 2.
USER SUPPLIED CABLE (SEE FIGURE 2) SCU WALL JACK ADDITIONAL KEYBOARDS AS NEEDED CM6700 SCU VIDEO INPUTS VIDEO OUTPUTS 1 1 3 5 7 9 11 13 15 2 3 2 4 6 8 10 12 14 16 4 KBD KBD 6' CABLE SWITCHER/CONTROLLER DATA CABLE WALL TRANSFORMER 10' CABLE KEYBOARD DATA CABLE Figure 3. Keyboard Cabling Diagram KEYBOARD DATA KBD300 RJ-45 CONNECTOR PIN 1 DIP SWITCH COVER PLATE PIN 1 2 3 4 5 6 7 8 FUNCTION TxD+ TxD12 VAC/DC NON POLAR GND } RxDRxD+ 1 2 3 4 KEYBOARD DIP SWITCH Figure 4.
3.2 KEYBOARD ADDRESSING NOTE: Assign keyboard addresses logically, in ascending order, to avoid confusion when keyboard access to monitors is programmed. The address assigned determines the keyboard number in the access menu. Each keyboard in the system must have a different address. To make programming easier, address keyboards in ascending order. Set the keyboard DIP switch address, refer to Figure 4. 1. Remove the two screws and the DIP switch cover plate from the rear of the keyboard. 2.
4.0 SPECIFICATIONS Keyboard Keypad: Mechanical Joystick: 3 axis, vector solving, with twisting return-to-center head 7-Segment Digital Display: Red LED, 2 cells Shift Mode Indicator: Green LED Electrical Input voltage: 12 VAC or ±12 VDC Power Consumption: 1 watt Ambient Operating Temperature: 20° to 120° F (-7° to 49° C) Humidity: 10% - 90% non-condensing Connector Type: RJ-45 8-pin modular (female) Keyboard Communication Protocol: RS-485 Baud Rate: 9600 General Dimensions: 9.50" x 7.
NOTES Pelco Manual C527M (11/97) 9
5.0 WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one (1) year after the date of shipment. Exceptions to this warranty are as noted below: • • • • • Two (2) years on all standard motorized and fixed focal length lenses. Two (2) years on Legacy®, Intercept ®, CM6700/CM8500/CM9500/CM9750/ CM9760 Matrix, Spectra™, DF5 Series and DF8 Fixed Dome products.