INSTALLATION/OPERATION IWM/IWM24 Series Wall Mount C288M-G (8/05)
Table of Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important Safety Instructions Read these instructions. 1. Keep these instructions. 2. Heed all warnings. 3. Follow all instructions. 4. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 5. Only use attachments/accessories specified by the manufacturer. 6. Refer all servicing to qualified service personnel.
Description IWM Series wall mount is designed for Spectra® Series pendant dome systems, and DF5 and DF8 fixed domes. The indoor/outdoor mounts can be installed directly to a wall or attached to an adapter and mounted to a corner, parapet, or pole mount. The mounts support maximum loads of 75 lb (34 kg) and feature cable feedthrough holes to conceal wiring. The IWM24 Series mount has a 24 VAC, 100 VA transformer with selectable input power (120/240 VAC, 50/60 Hz).
Installation IWM-BK AND IWM-GY 1. Determine the mounting location. If the mount is to be attached to a corner, parapet, or pole mount adapter, install the adapter plate (refer to the instructions supplied with the adapter). If the mount is to be attached to a wall, use the base of the IWM mount as a template and mark the four fastener positions on the mounting surface. Set the IWM mount to the side and prepare the holes for the fasteners. 2. Pull the wiring through the mount.
2. Install the conduit fittings or glands. Refer to one of the following installation methods: METHOD 1 – INSTALL A CONDUIT FITTING TO THE BOTTOM OF THE MOUNT • • Remove the 0.75-inch (1.91 cm) NPT plug. Install a conduit fitting in the 0.75-inch NPT hole. METHOD 2 – INSTALL THE CONDUIT FITTINGS/GLANDS TO THE BACK OF THE MOUNT • • Insert the male end of the gland or conduit fitting into the cable hole located on the back plate of the mount.
PULL WIRING 1. Refer to Table A and B for coaxial cable requirements and 24 VAC wiring distances. 2. Pull wiring/cabling for video and power. Refer to one of the following installation methods: METHOD 1 – THROUGH CONDUIT FITTINGS TO THE BOTTOM OF THE MOUNT If you are pulling video and power cables from the bottom of the mount, first attach the mount. Then pull the cables through the conduit in the bottom of the mount. Continue to pull the video cable only through the top of the mount.
INSTALL DOME 1. 2. Attach the dome back box to the mount and tighten the set screw. Make all necessary electrical connections to dome. (Use the documentation provided with the dome.) IMPORTANT: If you are wiring more than one dome, wire the power in each dome the same way. For example, the wiring from one side of the transformer must be connected to the corresponding connector on each dome.
Wiring Tables Table A. Video Coaxial Cable Requirements Cable Type* Maximum Distance RG59/U RG6/U RG11/U 750 ft (229 m) 1,000 ft (305 m) 1,500 ft (457 m) *Minimum cable requirements: 75 ohms impedance All-copper center conductor All-copper braided shield with 95% braid coverage The following are the recommended maximum distances for 24 VAC applications and are calculated with a 10 percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices.) Table B.
Specifications MECHANICAL Construction UNIT WEIGHT Cast aluminum Finish IWM-BK, IWM24-BK Black polyester powder coat IWM-GY, IWM24-GY Gray polyester powder coat Cable Entry IWM Series Mount One 0.75-inch (1.91 cm) NPT opening on the bottom of the mount IWM24 Series Mount Two cable feedthrough holes on the mounting plate accommodate 0.50-inch (1.27 cm) conduit fittings or PG13.5 liquid-tight gland fittings. One 0.75-inch (1.91 cm) NPT opening on the bottom of the mount for conduit connector.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. • Three years on Genex ® Series products (multiplexers, server, and keyboard).
. World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.