Manual

C3473M-C (10/10) 45
3. Remove the heater from the camera.
Figure 39. Removing the Heater
MOUNTING THE ENCLOSURE AND INNER DOME
1. Attach the inner dome carefully to avoid changing the lens direction.
2. Ensure that the tabs of the inner dome are secure.
3. Remove the pink cushioning from the inside of the dome and the protection sheet from the outside of the
dome.
4. Perform a back focus adjustment to correct any defocus that may have occurred when the enclosure was
reinstalled.
a. Press the [ABF2] button. The ABF operation indicator starts blinking.
b. While the indicator is blinking (for approximately 3 minutes), reattach the enclosure.
ì
Heater Output Connector
î
Screw