I N S T A L L A T I O N ICS-DO111ABK Integrated Camera System MR5000 Series Public Viewing System C2495M-A (1/06)
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 6. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 7. Only use attachments/accessories specified by the manufacturer. 8.
Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC, Class B (except auto iris models) RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to Part 15 of the FCC Rules.
Description Designed specifically for the MR5000 Series public viewing system, the ICS-DO111ABK integrated camera system packages a camera and lens into a small, discreet, high-security dome. Pelco’s MR5000 Series public viewing system is specifically designed for retail applications to provide a clear, visual warning to potential shoplifters that these premises are under surveillance. When properly installed the station is an effective deterrent against shoplifting.
Installation PREPARE VIDEO AND ELECTRICAL CABLING 1. Temporarily remove the bottom end cap of the MR5000 Series mount if the end cap is installed. 2. Feed the 42-inch video cable (provided) through the monitor feedthrough hole in the mount arm and out the bottom end of the mount arm. 3. Pull power wires through the ICS-DO111ABK feedthrough hole located at the bottom of the mount arm. Remove the 0.750-inch plug if it is installed.
INSTALL THE ICS-DO111ABK TO THE MR5000 MOUNT Follow the steps below to install the ICS-DO111ABK to the MR5000 mount: 1. Align the adapter plate with the cover. Position the cover so that the notch on the side of the cover faces the back of the MR5000 mount. ADAPTER PLATE COVER 10-32 x 0.375-INCH SCREWS AND WASHERS BACK BOX 8-32 x 0.375-INCH SCREWS AND WASHERS 2. Using the two 10-32 x 0.375-inch pan head screws and internal lock washers, attach the cover of the ICS-DO111ABK to the adapter plate.
3. Do the following to install the back box inside the cover of the ICS-DO111ABK: a. Feed the video cable and power wires attached to the ICS-DO111ABK back box through the cover and adapter plate of the ICS-DO111ABK. b. Rotate and position the back box so that the conduit plug on the side of the box is located on the opposite side (180 degrees) from the notch on the side of the cover. Use the supplied 8-32 x 0.375-inch screws and washers to secure the back box to the cover. 4.
Install Camera WARNING: Heater elements could be hot! When camera power is on, use caution when adjusting the camera. This applies to all models. 1. Some indoor installations do not require a heater. If the installation does not require a heater, remove the heater board from the camera assembly. To remove the heater press on an end of the board. HEATER BOARD 2. 12 VDC operation only: The camera is set for 24 VAC operation at the factory.
5. Always make sure the tab on the camera bracket is pointing out of the enclosure (away from the ceiling or wall). Gently squeeze the bracket, place it against the groove inside the back box, and gently release.
Install Dome and Trim Ring 1. Align the screw holes in the trim ring with those in the Camclosure base. 2. Domes with Liners (only) – ADJUSTMENT GROOVE DOME LINER Position the viewing window over the lens of the camera by doing the following: LOOSEN SCREWS a. Loosen the three Phillip screws located in the dome. b. Insert the blade of a standard screwdriver in one of the adjustment grooves. Move the dome into position. c. Tighten the three Phillip screws to lock the liner in place.
AUTO IRIS LEVEL ADJUSTMENT If you have a varifocal lens or fixed focal length lens with an auto iris, you can adjust the level setting to increase or decrease brightness. VARIFOCAL LENS FIXED LENS IRIS LEVEL ADJUSTMENT AUTO IRIS LEVEL ADJUSTMENT FOCUS ADJUSTMENT FOR FIXED FOCAL LENGTH LENS WITH AUTO IRIS WARNING: Heater elements could be hot! When camera power is on, use caution when adjusting the camera.
SWITCH SETTINGS FOR FIXED FOCAL LENGTH LENS WITH AUTO IRIS Refer to the switch drawing. The switch is located next to the lens. Automatic backlight compensation (factory setting) is used under varying lighting conditions (such as outdoors) or fi xed lighting conditions where there are no bright spots that darken other picture details. Manual backlight compensation is used in fixed lighting conditions to optimize the picture detail when there are bright spots.
SWITCH SETTINGS FOR VARIFOCAL LENS AE Functions The high resolution camera with varifocal lens and auto iris is confi gured at the factory for automatic exposure.
Specifications General Operating Temperature Finish Environment Unit Weight -50° to 122°F (-46° to 50°C) De-ices to 25°F (-4°C) 3/4-inch (1.91 cm) conduit fitting and 3/4-inch (1.91 cm) opening for NPT threaded pipe Manual; 360° pan; 180° tilt Aluminum with steel camera mounting bracket and polycarbonate dome Gray polyester powder coat Low temperature, indoor/outdoor 2.2 lb (1.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. • Three years on Genex® Series products (multiplexers, server, and keyboard).
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.