INSTALLATION/OPERATION ® IRD/ERD2000 Series Receiver C1506M-A (8/02)
C1506M-A (8/02)
CONTENTS Section Page IMPORTANT SAFEGUARDS AND WARNINGS ..................................................................................... 4 DESCRIPTION ..................................................................................................................................... 5 MODELS .................................................................................................................................... 5 MOUNTING ...................................................................
IMPORTANT SAFEGUARDS AND WARNINGS 1. 2. 3. 4. 5. Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 6. Do not install near any heat sources, such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 7. Only use attachments/accessories specified by the manufacturer. 8.
DESCRIPTION The IRD/ERD2000 Series Receiver operates Pelco’s fixed speed pan/tilts and domes. The receiver works with standard and extended Coaxitron® controllers, including the CM6700/ 7500/8500/9500, KBD9000, MPT9000/9008/9500, and MX4000. With Coaxitron control, pan/tilt and lens control signals are transmitted over the video coaxial cable. The control data is superimposed on the vertical blanking interval of the video signal.
ERD2200 WIRING POWER TERMINALS P/T GROUND STUD MAIN FUSE POWER SELECTOR SWITCH ENCLOSURE FUSE POWER TERMINALS (INSIDE) L Figure 2. ERD2200 Receiver 1. Fuses are installed for 115 VAC operation. For 230 VAC operation, install the appropriate fuses (supplied). Refer to Figure 2. GROUND STUD MAIN ENCLOSURE POWER OUT POWER IN N L N Figure 3. ERD2200 Power Connections Input Power 115 VAC 230 VAC Enclosure 4A 2A Main .5A .25A 2.
Rear View of Receiver ~ DEFAULT ~ SETTING 115/230V 24V FROM 50/60HZ 50/60HZ A A C C 24V 50/60HZ INPUT POWER ~ FACTORY 115/230V A A C C ERD OPTION P/T POWER SELECT Front View of Receiver CLASS 2 WIRING PWR VIDEO CX IN ERD OPTIONS 115/230V 50/60Hz .60 / .27 AMPS ~ ~ IRD 24V 50/60Hz 1.35 AMPS C PAN/TILT C ~ 24V ,1A CAM PWR I F Z LENS C 5V AUX1 C N N O C AUX2 OUT TLC Figure 4. ERD Wiring and Switch Setting 8.
IRD2024 WIRING Rear View of Receiver ~ ~ 115/230V 50/60HZ 24V 50/60HZ A A C C 24V 50/60HZ INPUT POWER ~ A A C C ERD OPTION P/T POWER SELECT Front View of Receiver CLASS 2 WIRING PWR VIDEO CX IN ERD OPTIONS 115/230V 50/60Hz .60 / .27 AMPS ~ ~ IRD 24V 50/60Hz 1.35 AMPS C PAN/TILT C ~ 24V ,1A CAM PWR I F Z LENS C 5V AUX1 C N N O C AUX2 OUT TLC Figure 5. IRD Wiring and Switch Setting 1. Connect power to the 24 VAC INPUT connector on the rear of the receiver.
OPERATION When power is applied to the receiver, the green PWR LED on the receiver lights. Whenever the receiver gets a valid Coaxitron control signal, the green CX LED blinks. RANDOM/AUTO SCANNING Operation of random and auto scanning depends on whether your transmitter/controller is communicating with the IRD2000/ERD2200 in standard or extended Coaxitron mode. Standard Coaxitron Press the Pan Auto (or Autoscan) key to begin random scanning.
FUSE REPLACEMENT CAUTION: These service instructions are for use by qualified service personnel only. To reduce the risk of electrical shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. IRD2024 Lens/Auxiliary Fuse A 500 mA fuse protects the LENS and AUX 1 outputs. Remove the cover of the receiver to check the fuse. ERD2200 Main Fuse The main fuse protects the pan/tilt output when 24 VAC pan/tilt operation is selected.
TROUBLESHOOTING Check the wiring connections. If the CX LED does not blink when commands are sent to the receiver, make sure the controller is working properly. Also check the video coaxial cable between the controller and the VIDEO OUT connection on the receiver. An LRD41TLC Test Local Control Module is available from Pelco to test or troubleshoot your receiver, pan/tilt, and lens functions directly from the receiver.
WIRING TABLES Table A. 24 VAC Wiring Distances Table The following are the recommended maximum wire distances (transformer to load) for 24 VAC applications and are calculated with a 10-percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices.) Distances are calculated in feet; values in parentheses are meters.
SPECIFICATIONS ERD2200 IRD2024 Electrical Electrical Input Voltage: 115/230 VAC, 50/60 Hz Output Voltage Camera: 24 VAC (or 115/230 VAC if using enclosure power) Lens: 8 VDC Pan/Tilt: 24/115/230 VAC Enclosure: 115/230 VAC Power Consumption Receiver: 90 VA maximum, including 48 VA maximum at 24 VAC for pan/tilt and camera (5 VA maximum for camera) Fuses Main: 115 VAC – .5A 230 VAC – .25A Enclosure: 115 VAC – 4A 230 VAC – 2A Lens/Aux 1: .
REGULATORY NOTICES NOTE: This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • • • • • • • • • Five years on Pelco manufactured cameras (CC3500/CC3600/CC3700 and MC3500/MC3600 Series); two years on all other cameras. Three years on Genex® Series (multiplexers, server, and keyboard).
® World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.