FIGURE 7 – LED INDICATORS
FIGURE 6 – CONTACT SWITCH POSITIONS
LINK VIDEO (1 – 8) DATA (1 – 2) POWER
GREEN Communication link has been
established over optical fiber
Active video signal present
on the BNC connector.
Active data signal
present
Unit powered up
RED Communication link has not been
established
No video signal No data signal
OFF Not powered up correctly Unit powered down
LINK
VIDEO 1
VIDEO 2
VIDEO 3
VIDEO 4
POWER
VIDEO 5
VIDEO6
VIDEO 7
VIDEO8
GND
+Vin
PWR
1234
OPTICAL
IN/OUT
VIDEOOUT
5678
DATA 1
DATA 2
DATA 1
12 12
DATA 2
ON
CONTACT
1234
DATA 1
GND
BIAS
DOUT -
DOUT +
TERM
DIN -
DIN +
DATA 2
GND
BIAS
DOUT -
DOUT +
TERM
DIN -
DIN +
OUT
OUT
IN
IN
CONTACT
FRV80D2S1ST
8CHANNELDIGITAL VIDEO
RECEIVER
+
2CHANNELSOF
BI-DIRECTIONAL DATA
+
BI-DIRE CTIONAL CONTACT
LINK
VIDEO 1
VIDEO 2
VIDEO 3
VIDEO 4
POWER
VIDEO 5
VIDEO6
VIDEO 7
VIDEO8
GND
+Vin
PWR
1234
OPTICAL
IN/OUT
VIDEOOUT
5678
DATA 1
DATA 2
DATA 1
12 12
DATA 2
ON
CONTACT
1234
DATA 1
GND
BIAS
DOUT -
DOUT +
TERM
DIN -
DIN +
DATA 2
GND
BIAS
DOUT -
DOUT +
TERM
DIN -
DIN +
OUT
OUT
IN
IN
CONTACT
FRV80D2S1ST
8CHANNELDIGITAL VIDEO
RECEIVER
+
2CHANNELSOF
BI-DIRECTIONAL DATA
+
BI-DIRE CTIONAL CONTACT
The four CONTACT switches on the front of the unit set the operating mode of the
CONTACT OUT terminal pair.
It can either function as an alarm to indicate fault conditions, or it can function as a
contact closure to indicate the state of the CONTACT IN terminal pair on the rear of the
unit at the other end of the fiber.
1 2 3 4
ON OFF OFF OFF Closed when optical Port has established link.
Open when Optical Port has lost link.
ON ON ON OFF Closed when Optical Port has established link and all video signals are present.
Open when Optical Port has lost Link, or if a Video signal is lost.
ON ON ON ON Contact Closure mode.
State based on CONTACT IN at other end of fiber link.