I N S T A L L A T I O N FT8301A/FR8301A Fiber Transmitter and Receiver Single-Channel Digitally Encoded Video C1679M (1/06)
Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9.
The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. C1679M (1/06) CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN.
Regulatory Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC Rules.
Product Overview DESCRIPTION The FT8301A/FR8301A fiber transmitter and receiver provide the ability to transmit one composite video channel over one optical fiber (refer to Figure 1). . ONE VIDEO INPUT FT8301A TRANSMITTER ONE VIDEO OUTPUT ONE FIBER COMPATIBLE RECEIVER ONE VIDEO INPUT COMPATIBLE TRANSMITTER ONE VIDEO OUTPUT ONE FIBER FR8301A RECEIVER Figure 1.
MODELS The FT8301A/FR8301A fiber transmitter and receiver consist of the following series of models: Multimode Models:* FT8301AMSTR Single-channel fiber optic video transmitter; multimode, ST connector; transmission distance up to 2 km FR8301AMSTR Single-channel fiber optic video receiver; multimode, ST connector; transmission distance up to 2 km FT8301AMSTRE Single-channel fiber optic video transmitter; multimode, ST connector; transmission distance up to 6 km (extended distance) FR8301AMSTRE Single
FRONT PANEL The front panel of the FT8301A transmitter and the FR8301A receiver provides LED indicators that allow you to monitor signal status, laser status, and operating power (refer to Figure 2). 1 FT8301A TRANSMITTER 1 FR8301A RECEIVER Figure 2. Front Panel of FT8301A Transmitter and FR8301A Receiver VIDEO PRESENT LED OPTIC FAULT LED POWER LED (Pelco badge) For detailed information about the front-panel indicators, refer to the Troubleshooting section.
REAR PANEL Connections to the FT8301A transmitter and FR8301A receiver are made to the rear panel of the modules (refer to Figure 3). + - 1 FT8301A TRANSMITTER + - 1 FR8301A RECEIVER Figure 3.
Installation PACKAGE CONTENTS The following items are supplied: 1 FT8301A transmitter or FR8301A receiver 1 Regulated switching power supply with four plug adapters (North American, Australian, U.K., and European configurations); 100-240 VAC, 50-60 Hz input, 12 VDC output 1 Wall clip with two 4-40 x .
MOUNTING THE TRANSMITTER/RECEIVER TO A WALL The FT8301A transmitter/FR8301A receiver can be mounted to a wall in the following ways: • Using the supplied wall clip for attachment of a single module to a wall. For installation instructions, refer to the Mounting the Transmitter/Receiver Using the Wall Clip section. • Using the optional WM5001 wall mount kits, which are designed for mounting of single-width fiber optic modules. The WM5001-3U base kit allows mounting of a single module to the wall.
UPPER FLANGE VERTICAL MOUNTING HOLE (2) HORIZONTAL MOUNTING HOLE (2) TRANSMITTER/ RECEIVER SCREW, PHILLIPS PAN HEAD WITH LOCK WASHER (2) WALL CLIP LOWER FLANGE Figure 4.
CONNECTIONS Connections to the FT8301A transmitter and the FR8302A receiver are made on the rear panel of the modules and consist of the following: • Power connection NOTES: – A 12 VDC or 24 VAC power supply can be used to power the transmitter/receiver when used as a standalone module. A 12 VDC power supply is provided. If a 24 VAC power supply is used, the power supply must be a Listed Direct Plug-In Power Unit marked as Class 2 and rated as 24 VAC, 200 mA (minimum output).
POWER/ALARM CONNECTION FOR RACK-MOUNTED MODULE POWER CONNECTION FOR STANDALONE MODULE FIBER OPTIC CABLE + - 1 UTP WIRES OR COAXIAL CABLE Figure 6.
Troubleshooting LED indicators on the front panel of the FT8301A transmitter/FR8301A receiver (refer to Figure 2) allow you to monitor signal status, laser status, and operating power. Table A provides information about the front-panel indicators and associated troubleshooting guidelines. Table A. Troubleshooting with Front-Panel Indicators Indicator Color Meaning Possible Cause Corrective Action Power LED (Pelco badge) Blue Pelco logo lights. Power is being applied – to the module.
Table A. Troubleshooting with Front-Panel Indicators (Continued) Indicator Color Meaning Possible Cause Corrective Action Optic Fault LED - Transmitter Green Laser is operating properly. – No action required. Flashing red Laser has shut down. Transmitter is operating in extreme conditions, for example, operating temperature is below or above recommended range as stated in the the Specifications section.
Specifications VIDEO Number of Channels Modulation Type Video Input (FT8301A)/ Video Output (FR8301A) Bandwidth Gain Differential Gain Differential Phase Tilt Signal-to-Noise Ratio GENERAL Operating Temperature Input Power Requirements LED Indicators Dimensions Unit Weight MECHANICAL Connectors Video Rack Power/Alarm Standalone Power Fiber Optic 18 1 Pulse code modulation, 8-bit resolution BNC, 1.0 Vp-p, 75 ohms or UTP, 100 ohms; NTSC, PAL, and SECAM 6.
OPTICAL POWER BUDGET, TRANSMISSION DISTANCE, AND LASER CLASS 1 LIMIT FT8301A TRANSMITTER AND COMPATIBLE RECEIVERS FT8301A Transmitter Compatible Receivers Wavelength Optical Power Budget Maximum Transmission Distance Laser Class 1 Limit* Multimode (62.5/125 µm) FT8301AMSTR FR8301AMSTR FR8302AMSTR-2 850 nm 20 dB† 2 km (1.2 mi)†† <0.78 mW FR8301MSTR 850 nm 15 dB† 2 km (1.2 mi)†† <0.78 mW Multimode - Extended Distance (62.
OPTICAL POWER BUDGET, TRANSMISSION DISTANCE, AND LASER CLASS 1 LIMIT FR8301A RECEIVER AND COMPATIBLE TRANSMITTERS FR8301A Receiver Compatible Transmitters Wavelength Optical Power Budget Maximum Transmission Distance Laser Class 1 Limit* 2 km (1.2 mi)†† <0.78 mW Multimode (62.5/125 µm) FR8301AMSTR FT8301AMSTR FT8301AMST FT8301MST FR8301AMSTRE FT8301AMSTRE FT8301AMSTE FT8301MSTE 850 nm 20 dB† Multimode - Extended Distance (62.5/125 µm) 1310 nm 26 dB† 6 km (3.7 mi)†† <15.
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. • Three years on Genex® Series products (multiplexers, server, and keyboard).
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.