C3952M-B (5/14) 9
PARTS LIST
The following installation tools and parts are supplied:
USER-SUPPLIED PARTS LIST
The following installation tools and parts are needed but not supplied:
Network/power cabling
#2 Phillips screwdriver
Standard flat head screwdriver
Mounting hardware
Glands for conduit plate
GENERAL INFORMATION
If installing conduit, the cabling/wiring must conform to local code for protection against environmental conditions when exiting from a building
or outdoor-rated termination box.
The fortified camera system is environmentally sealed (IP66, NEMA Type 4X rating) in the camera enclosure and area of the mount arm where
data cables/wires are terminated. The remainder of the mount arm is rated IP54, NEMA 3R.
The power supply types must be LPS or class 2 rated for FH-L Series (low temperature), FH-M Series (high humidity), and FH-S Series (12 VDC).
The FH-L Series (low temperature) models are equipped with a “cold start” feature. This feature prevents the camera from powering on if the
temperature inside the enclosure is below –23°C (–10°F). When power is restored, the camera power will not turn on until the enclosure reaches
an acceptable temperature for proper camera operation. Therefore, the camera might not turn on for an hour or more in extreme temperatures of
–60°C (–76°F). Failure to provide the specified operating voltage will disable this feature and prevent camera operation. Refer to Verifying Input
Voltage on FH-L and FH-M Series Models on page 16 for proper operation.
The FH-H Series (high temperature) power supply unit is located in the wall mount arm. A 15 or 20 amp breaker must protect the wiring from the
building prior to connecting the FH-H Series power unit. The high voltage (power) and low voltage (data) cabling must be routed separately
through the two conduit plate entry holes. A plate inside the FH-H Series housing maintains separation of power and data supply.
Qty Description
1 FH Series fortified camera system (enclosure, wall mount, camera, lens, power supply)
1 Conduit plate
1 Conduit plate gasket
1 Reusable desiccant canister (REACh compliant) silica gel pack
1 Duplex fiber gland bushing (two-hole)
1 Ethernet female-to-female adapter
1 Fiber optic connector (FSFP module)*
1 PG9 data gland
1 PG9 data gland locknut
*Supplied only with FH*-F models.