FH-L, FH-M, AND FH-S SERIES ENCLOSURE MODELS
1. Remove the desiccant canister (supplied) from its packaging.
2. Place the desiccant canister in the enclosure near the camera, making sure the small inspection window on the desiccant canister is facing
the camera (refer to Figure 13).
3. Close the lid and tighten the screws to seal the enclosure.
The desiccant canister reduces condensation within the enclosure. When the orange beads in the inspection window become clear, reactivate
the desiccant canister by placing it in a vented 150°C (300°F) oven for at least three hours, or until the beads are orange.