Installation Manual

9 C1354M-D (1/19)
Figure 9. Grounding Screw (left) and Wiring Connections: 100 to 240 VAC (right)
4. Route the wires and cables through the center of the Esprit mount. Reinstall the power module into the base. The power module can be
positioned in the mount base in only one orientation.
Figure 10. Reinstalling the Power Module
5. Connect wires and cables.
a. Connect to power. Use the supplied 2-pin screw connector to connect the AC line and neutral using 16 AWG wire. Use the pre-
installed grounding lug and screw to connect Ground to the unit using 12-16 AWG wire.
ì
Connects 100 to 240 VAC power to the system
î
Connects the system to IP network
ï
Connects 1 or 2 SFP modules (SFP Port 1 will auto-detect either 100 Mbps and 1 Gbps speeds. SPF Port 2 follows the speed
of Port 1 and requires a module in Port 1. Ensure the same speed transceivers are being used if both ports are utilized.)
Connects up to 2 relays, 4 alarms, audio, and reset using 16-20 AWG wire
Power Wire Description
Label Function
L Line
N Neutral
Earth Ground
Port 1 Port 2
Grounding Screw