Installation Manual

7 C1354M-D (1/19)
4. Route the wires and network cable through the center of the Esprit mount.
5. Connect power using the supplied 2-pin screw connector using 16-20 AWG wire gauge. Connect the Cat5e cable to the RJ-45 connector
and/or connect the SFP module(s). Connect AUX (optional). Refer to Connecting AUX (optional) on page 10.
NOTE: No grounding lug or screw is provided.
Figure 5. Wiring Connections: 24 VAC
6. Attach the included ferrite to the network cable as close as possible to the RJ-45 connector to reduce radio frequency electrical
interference on the network cable. The cable should have one turn/loop around the ferrite core.
7. Reinstall the power module assembly into the base. The power module assembly can be positioned in the mount base in only one
orientation.
Figure 6. Reinstalling the Power Module
ì
Connects 24 VAC or 48 DC power to the system
î
Connects HPoE power to the system and connects the system to IP network
ï
Connects 1 or 2 SFP modules (SFP Port 1 will auto-detect either 100 Mbps and 1 Gbps speeds. SFP Port 2 follows the speed
of Port 1 and requires a module in Port 1. Ensure the same speed transceivers are being used if both ports are utilized.)
Connects up to 2 relays, 4 alarms, audio, and reset using 20-26 AWG wire
Power Wire Description
Label Function
+ +24 VAC or +48 VDC
- -24 VAC, -48VDC, or DC GND
Port 1 Port 2