I N S T A L L A T I O N DF8 Series Pendant Dome C2433M-E (11/06)
Contents Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Description . . . . . . . . . . . . . . . . . . . . . . . .
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 6. Do not install near any heat sources, such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 7. Only use attachments/accessories specified by the manufacturer. 8.
Description DF8 Series pendant domes are discreet surveillance domes that are designed for indoor or outdoor use. Indoor pendant models come in light gray or black finish. Outdoor pendant models are light gray only and include a heater that allows operation down to -60°F (-51°C). MODELS 4 DF8-PB-0 Indoor, black, fixed mount pendant dome, black opaque lower dome with smoked viewing window (0.
Installation PARTS LIST The DF8 shipping carton contains two boxes. Inspect each box to make sure all parts are present. BACK BOX Qty Description 1 Back box 1 Parts bag 1 Flat washer 1 Split lock washer 1 Screw 1 Thread compound LOWER DOME Qty Description 1 Acrylic lower dome with trim ring 1 Parts bag 1 O-ring 1 O-ring lubricant 1 Loctite® threadlocker BACK BOX PENDANT MOUNT NOTE: If installing outdoors, make sure the back box is properly sealed to keep moisture out. 1.
SURFACE MOUNT NOTE: If installing outdoors, apply a sealant between the back box and the mounting surface. 1. Unscrew the three Phillips screws located inside the back box. Remove the top portion of the back box. Figure 2. Removing the Top Mount from the Back Box 2. Determine the mounting location. Use the base of the back box as a template. Mark the fastener and center hole positions onto the mounting surface. 3. Prepare the holes for the wiring and fasteners. 4.
Table A. Video Coaxial Cable Requirements Cable Type* Maximum Distance RG59/U 750 ft (229 m) RG6/U 1,000 ft (305 m) RG11/U 1,500 ft (457 m) *Cable requirements: 75 ohms impedance All-copper center conductor All-copper braided shield with 95 percent braid coverage Table B. 24 VAC Wiring Distances The following are the recommended maximum distances for 24 VAC applications and are calculated with a 10 percent voltage drop.
CAMERA AND LENS To install the camera and lens: 1. For outdoor models, connect 24 VAC power input wires to the AC IN connectors on the terminal block on the side of the back box. 2. Extend the lens to the maximum length before installing the camera in the back box. 3. Attach the camera to the tilt table with the 1/4-20 screw, flat washer, and split lock washer (supplied). 4. To ensure that the lens will not hit the lower dome: a.
3. Attach the trim ring leash to the T-shaped sheet metal tab on the retaining ring of the lower dome. Tuck the end of the trim ring leash behind the raised sheet metal stop, and make sure the leash will hold the lower dome. LEASH ATTACH LEASH TO SHEET METAL TAB MOUNTING SCREW HOLES FRONT & BACK Figure 5. Attaching the Trim Ring Leash 4. Remove the two mounting screws. Apply a drop of Loctite threadlocker #222 (supplied) to each screw.
Maintenance Clean the acrylic dome as needed. Be careful not to scratch the surfaces of the dome. EXTERIOR SURFACE Clean the dome’s exterior surface with a nonabrasive cleaning cloth and agent that is safe for acrylic plastic. Either liquid or spray cleaner/wax suitable for fine furniture is acceptable. INTERIOR SURFACE SMOKED OR CLEAR Clean the same as the exterior surface. CHROME OR GOLD The inside surface of a chrome or gold dome is easily scratched.
Specifications ELECTRICAL Input Voltage 14-30 VAC (outdoor models only) Input Power 58 VA at 24 VAC (for heater and blower) GENERAL Construction Back Box Mounting Bracket Lower Dome Trim Ring Aluminum Steel Acrylic Aluminum Environment Indoor and outdoor Operating Temperature Indoor Outdoor* 32° to 120°F (0° to 49°C) -60° to 122°F (-51° to 50°C) continuous operation -50° to 122°F (-46° to 50°C) continuous operation; prevents icing -40° to 122°F (-40° to 50°C) continuous operation; de-ices within 3
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FR/FT/FS Series fiber optic products and TW3000 Series unshielded twisted pair transmission products. • Three years on Genex® Series products (multiplexers, server, and keyboard).