I N S T A L L A T I O N DF5 Series Fixed Mount Dome C1458M-J (9/08)
Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 6. Do not install near any heat sources, such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 7. Only use attachments/accessories specified by the manufacturer. 8.
Description DF5 Series domes are discreet surveillance domes that are designed for indoor or outdoor use. Models include pendant and in-ceiling versions. In-ceiling models have plenum-rated back boxes and can be installed in hard ceilings or standard 2 x 2 ft (6 x 61 cm) suspended ceilings. Indoor pendant models come in light gray or black finish. Outdoor pendant models are light gray only and include a heater that allows operation down to -60°F (-51°C).
Installation PARTS LIST The DF5 shipping carton contains two boxes. Inspect each box to make sure all parts are present.
BACK BOX IN-CEILING MODELS, HARD CEILINGS 1. Locate the center point of the mounting location. Drill a hole in the ceiling using a 3/32-inch drill. Insert the compass tool into the hole. Use a pencil and the compass tool to draw a circle on the ceiling. Carefully cut out the circle. Figure 1. Preparing the Ceiling 2. Attach a conduit fitting (not supplied), lock nut (not supplied), and safety chain bracket. Install a safety chain/cable (not supplied) that will support up to 16 pounds (7.3 kg).
IN-CEILING MODELS, SUSPENDED CEILING 1. Remove the ceiling tile from the ceiling. Insert the compass tool (supplied) into the center of the tile. (If necessary, use a 3/32-inch bit to drill a hole.) Draw a circle on the tile using the compass tool and a pencil. Carefully cut out the circle. NOTE: The ceiling tile cannot be thinner than 0.50-inches (1.27 cm) or thicker than 1.75 inches (4.45 cm). Figure 4. Preparing the Ceiling Tile 2.
PENDANT MODELS, SURFACE MOUNT 1. If you have an outdoor model, remove the sun shield. 2. Remove the black tilt table assembly inside of the back box by removing the nuts and washers that hold the three legs to the back box. 3. Remove the top mount by removing the three screws and lock washers inside the back box. Figure 6. Removing the Top Mount from the Back Box 4. Using the back box as a template, mark the three fastener holes and the center hole for wiring.
CAMERA AND LENS If the camera and lens are already installed, begin with step 2. 1. If applicable, extend the lens to the maximum length before installing the camera in the back box. Attach the camera to the tilt table with the 1/4-20 screw, flat washer, and lock washer (supplied). IN-CEILING MODEL PENDANT MODEL Figure 8. Installing the Camera and Lens 2. For indoor models, connect the power wires and video cable to the camera. 3. For outdoor models, connect the video cable to the camera.
LOWER DOME IN-CEILING MODELS 1. Snap the clip on the end of the trim ring leash into the hole on the lip of the back box. 2. Line up the snaps on the trim ring with the mounting screws on the back box. Snap the trim ring into the plastic snap washers on the mounting screws. Figure 10. Installing the Lower Dome for In-Ceiling Models PENDANT MODELS 1. Hanging down from the back box is a flexible strap called the trim ring leash.
Maintenance Clean the acrylic dome as needed. Be careful not to scratch the surfaces of the dome. EXTERIOR SURFACE Clean the dome’s exterior surface with a nonabrasive cleaning cloth and agent that is safe for acrylic plastic. Either liquid or spray cleaner/wax suitable for fine furniture is acceptable. INTERIOR SURFACE SMOKED OR CLEAR To clean the interior of smoked or clear domes, use the same instructions as the exterior surface.
Specifications ELECTRICAL Input Voltage Input Power 24 VAC (outdoor models only) 58 VA (for heater) MECHANICAL Construction Back Box Mounting Bracket Lower Dome Trim Ring Indoor Aluminum Steel Acrylic Eggshell white molded plastic, UL94V0 Outdoor Plastic GENERAL Environment Operating Temperature Indoor Outdoor* Indoor or outdoor (depends on model) 32° to 120°F (0° to 49°C) -60° to 122°F (-51° to 50°C), continuous operation -50° to 122°F (-46° to 50°C), continuous operation; prevents icing -40° to 122
Appendix Table A. Video Coaxial Cable Wiring Distances Cable Type* Maximum Distance RG59/U 750 ft (229 m) RG6/U 1,000 ft (305 m) RG11/U 1,500 ft (457 m) *Cable requirements: 75-ohm impedance All-copper center conductor All-copper braided shield with 95% braid coverage Table B shows are the recommended maximum distances for 24 VAC applications and are calculated with a 10 percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices.) Table B.
REVISION HISTORY Manual # C1458M C1458M-A C1458M-B Date 4/97 7/97 12/97 C1458M-C C1458M-D 2/98 5/98 C1458M-E 6/98 5/00 C1458M-F C1458M-G C1458M-H C1458M-I C1458M-J 1/02 8/02 5/05 7/06 11/06 9/08 Comments Original version. Added indoor pendant models. Added DF5C and DF5M pendant models. Added outdoor pendant models. Removed column for 22-gauge wire from Table B. Added dimensions for pendant models to Figure 17. Deleted references to SD5-P, which is covered in C1459M.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on fiber optic products and TW3000 Series unshielded twisted pair (UTP) transmission products. • Three years on Spectra® IV products. • Three years on Genex® Series products (multiplexers, server, and keyboard).
Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: (800) 289-9100 Fax: (800) 289-9150 International Tel: +1 (559) 292-1981 Fax: +1 (559) 348-1120 www.pelco.