TABLE OF CONTENTS Section 1.0 2.0 3.0 4.0 5.0 6.0 7.0 Page WARNINGS ........................................................................................................................................ 1 SCOPE ...............................................................................................................................................2 DESCRIPTION ...................................................................................................................................
INSTALLATION/OPERATION MANUAL BREAKOUT PANELS FOR VA6000 SERIES SWITCHER AND CM8500 MATRIX SYSTEM 1.0 WARNINGS Prior to installation and use of this product, the following WARNINGS should be observed. 1. Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
2.0 SCOPE The information contained within this manual covers the installation and operation of the Alarm Breakout Panels for the VA6000 Series Switcher and the Alarm, Wiretron and Relay Breakout Panels for the CM8500 Matrix system. 3.
Figure 1.
The table below lists the pin-out relationship between the alarm panel header, J2, and the 15-pin connector on the rear of the VA6000 switcher for 8 input alarms. The pattern serves equally well for VA models with 4 input alarms: the first 4 Pin Numbers correspond to like numbered ALM numbers, with pins 5-10 unused and pins 11-15 serving the same functions as in the 8 input VA6000 Switcher model. Alarm Pin-outs 1-8/VA6000 Rear Panel Connector ALM # 15-Pin Female Conn.
The table below lists the pin-out relationship between the alarm panel header, J1, and the 25-pin connector on the rear of the VA6000 switcher for 20 input alarms. The pattern serves equally well for VA models with 12 input alarms: the first 12 Pin Numbers correspond to like numbered ALM numbers with pins 13-20 unused and pins 21-25 serving the same functions as in the 20 input VA6000 Switcher models. Alarm Pin-outs 1-16/CM8500 Rear Panel-P4 ALM # 25-Pin Female Conn.
PCB LAYOUT CABLE ASSEMBLY ALARM BREAKOUT PANEL (PCB9000582) Mounting Plate WIRING SCHEMATIC Figure 4.
The table below lists the pin-out relationship between the alarm panel header, J1, and P4 on the CM8500 for the first 16 alarms. The pattern serves equally well for alarms 17-32: P4 becomes P3 and the listed alarms go from 17-32 instead of 1-16. Alarm Pin-outs 1-16/CM8500 Rear Panel-P4 ALM # Alarm 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 ... 2 ... 3 ... 4 ... 5 ... 6 ... 7 ... 8 ... 9 ... 10 ... 11 ... 12 ... 13 ... 14 ... 15 ... 16 ... Pin Number Com ... 20 ... 21 ... 22 ... 23 ... 24 ... 25 ... 26 ...
WIRETRON BREAKOUT PANEL (PCB9000583) Mounting Plate RIBBON CABLE WIRING SCHEMATIC Figure 6.
The table below lists the pin-out relationship between the wiretron panel header, J1, and P5 on the CM8500 for the first 16 wire control positions. The pin mappings serve equally well for wire controls 17-32: P5 becomes P6 and the listed WIR numbers go from 17-32 instead of 1-16. J1 Header Pin-out on Wiretron Breakout Panel for CM8500 Pin Number Wire Control Pin-outs 1-16/CM8500 Rear Panel-P5 WIR # Pin Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 ... 3 ... 5 ... 7 ... 9 ... 11 ... 13 ... 15 ... 20 ...
PCB LAYOUT RIBBON CABLE ASSEMBLY RELAY BREAKOUT PANEL (PCB9000581) Mounting Plate WIRING SCHEMATIC Figure 8.
Figure 9. Installation Configuration for the CM8500 Wiretron Breakout Panel Figure 10.
The table below lists the pin-out relationship between the relay panel header, J1, and P1 on the CM8500 for the first 16 relay output positions. The pin mappings serve equally well for relay outputs 17-32: P1 becomes P2 and the listed RELAY numbers go from 17-32 instead of 1-16. Relay 1-16 Pin-outs CM8500 Rear Panel-P1 RELAY # Pin Number NC NO COM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 ... ... 4 ... ... 7 ... ... 10 ... ... 13. ... ... 16 ... ... 19 ... ... 22 ... ... 25 ... ... 28 ... ..
5.0 MODELS VA6008-APNL-2 VA6008-APNL-10 VA6020-APNL-2 CM8500-WPNL-2 VA6000 alarm breakout panel for up to 8 alarm inputs; 2-foot (.609 m) interconnecting ribbon cable supplied. Same as VA6008-APNL-2, except 10-foot (3.048 m) interconnecting ribbon cable. VA6000 alarm breakout panel for up to 20 alarm inputs; 2-foot (.609 m) interconnecting ribbon cable supplied. VA6020-APNL-10 Same as VA6020-APNL-2 except 10-foot (3.048 m) interconnecting ribbon cable.
7.0 WARRANTY AND RETURN INFORMATION WARRANTY RETURNS Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FT/FR8000 Series fiber optic products. • Three years on Genex® Series products (multiplexers, server, and keyboard).