I N S T A L L A T I O N 090 Series Camclosure® Indoor Integrated Camera System Surface Mount/In-Ceiling C2462M-E (3/09)
Contents Important Safety Instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Parts List. . . . . . . . .
List of Illustrations 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Removing the Dome Bubble. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Ceiling/Wall Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Concrete Ceiling/Wall Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Ceiling Tile Installation.
Important Safety Instructions 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes. 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and must not be installed where exposed to rain and moisture. 3. Use only installation methods and materials capable of supporting four times the maximum specified load.
Description The ICS090 Series Camclosure® integrated camera system integrates a camera and lens package in a small, discreet dome. The system is easy to install and can be mounted or recessed to the surface of a ceiling or wall. Prior to the installation of your new system, thoroughly familiarize yourself with the information in this manual.
Remove the Dome Bubble Turn the dome bubble counterclockwise and lift (refer to Figure 1). Place the bubble on a nonabrasive surface. If the unit is supplied with a dome liner, remove the liner before installing the unit. To remove the liner, gently lift it from the unit. Place the liner to the side; it will be reinstalled along with the bubble after the installation has been completed following installation. Figure 1.
Installation The installation methods for the ICS090 Series include the following options: • Mount to the surface of a ceiling or wall • Install in a suspended ceiling • Install in a fixed ceiling or wall • Mount to the surface of a 4S standard electrical box • Install in a 4S deep electrical box SURFACE INSTALLATION: CEILING/WALL Refer to Figure 2 on page 8 for the following steps. Refer to Figure 3 on page 8 if you are installing the unit to the surface of a concrete ceiling or wall. 1.
4. Use 6-32 toggle bolts (not supplied) to attach the surface mount ring and back box to the mounting surface (refer to Figure 2). NOTE: For a concrete ceiling or wall installation, use 8-32 mounting hardware (not supplied), refer to Figure 3. Figure 2. Ceiling/Wall Installation Figure 3.
IN-CEILING INSTALLATION: SUSPENDED CEILING 1. Remove the ceiling tile from the ceiling (refer to Figure 4). 2. Cut a 4-inch diameter hole in the ceiling tile. 3. Remove the surface mount ring from the back box (refer to Figure 5 on page 10): a. Place your fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the back box. Do not discard the surface mount ring because it is required to complete the installation.
STANDOFF BACK BOX SURFACE MOUNT RING Figure 5. How to Remove Surface Mount Ring from Back Box AC operation only: If you are wiring more than one Camclosure to the same transformer, connect one side of the transformer to the red wire on all units; connect the other side of the transformer to the black wire on all units. NOTE: Failure to connect all of the units in the same way will cause the cameras to be out of phase with each other, which might produce a vertical roll when switching between cameras.
IN-CEILING INSTALLATION: FIXED CEILING OR WALL 1. Cut a 4-inch diameter hole in the ceiling/wall (refer to Figure 6 on page 11). 2. Remove the surface mount ring from the back box (refer to Figure 5 on page 10). a. Place your fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the back box. Do not discard the surface mountring, it is required to complete the installation. 3. Connect the video cable and wires.
SURFACE INSTALLATION: 4S STANDARD ELECTRICAL BOX 1. Attach the adapter ring to the 4S box with two 8-32 x 1.00-inch screws (supplied; refer to Figure 7). 2. Connect the video cable and wires. BNC: Connect the BNC connector from the Camclosure to a mating BNC connector. Twisted pair: Connect the blue wire to Video +; connect the gray wire to Video -. 3. Connect the power wires (refer to Table D). Table D.
IN-CEILING INSTALLATION: 4S DEEP ELECTRICAL BOX 1. Remove the surface mount ring from the back box (refer to Figure 8): a. Place your fingers on the circular marks located on the sides of the surface mount ring. b. Pinch the sides. c. Lift and remove the surface mount ring from the back box. 2. Attach the adapter ring to the 4S box with two 8-32 x 1.00-inch screws (supplied). 3. Connect the video cable/wires. BNC: Connect the BNC connector from the Camclosure to a mating BNC connector.
Camera Positioning Manually rotate and tilt the camera module to position the camera. Do not over-rotate the module. WARNING: Excessively turning the module in one direction could result in damage to the wiring. ì Tilt 140° (20° to 160°) î Pan 360° ï Rotation 360° Figure 9.
Camera Adjustments SWITCH SETTINGS FIXED FOCAL LENGTH LENS WITHOUT AUTO IRIS Refer to the switch drawing. The switch is located next to the lens. Automatic backlight compensation (factory setting) is used under varying lighting conditions (such as outdoors) or fixed lighting conditions where there are no bright spots that darken other picture details. Manual backlight compensation is used in fixed lighting conditions, to optimize the picture detail when there are bright spots.
FOCUS ADJUSTMENT NOTE: You will need a miniature Phillips or flat-tip screwdriver to loosen and tighten the locking screw. To adjust the focus: 1. Loosen the focus locking screw. 2. Position the inverted dome approximately 0.125 inch (3.175 mm) from the front of the lens. Make sure that the lens and the dome are centered (refer to Figure 11). 3. Turn the focus locking screw clockwise or counterclockwise to adjust the focus. 4. When the optimal focus is reached, tighten the focus locking screw. FOCUS 0.
VERTICAL PHASE ADJUSTMENT (24 Vac Operation Only) When using more than one camera power supply, a brief vertical roll may occur on the monitor when a camera view is switched. To eliminate vertical roll, reverse the 24 VAC connections on one camera. If both cameras are connected to the same transformer, this should solve the problem. If reversing the connections does not solve the problem, adjust the phase control by synchronizing, or line-locking, the cameras to one another.
Install Liner and Bubble DOME LINER INSTALLATION If the unit is supplied with a dome liner, reinstall the liner before installing the dome bubble (refer to Figure 13): 1. Align the studs located on the camera module with the clips on the liner. 2. Lightly pinch the sides of the liner, opposite from the clips, and place the clips over the studs. 3. When the liner is secure, position the viewing window of the liner over the lens of the camera. 4.
DOME BUBBLE INSTALLATION To install the dome bubble (refer to Figure 14): 1. Select the bubble (clear or smoked). 2. Align the standoffs of the bubble with the slots of the back box. 3. Turn the bubble clockwise until it locks in place. Figure 14.
Service Connector An optional 4-foot service/monitor cable, part number ICS090-SC, is available for on-site setup and adjustments. To use the cable, simply plug one end of the cable directly into the service connector of the ICS090, and then connect the other end to any standard BNC (VIDEO IN) connector on a monitor. To assemble a longer service cable for the ICS090 Series Camclosure, purchase the following parts at a local electronics supply store: Qty Description 1 2.
Specifications ELECTRICAL Input Voltage* Power Consumption Video Connector 12 VDC or 24 VAC (±10%), autosensing 3 W or less BNC *24 VAC power is recommended when installing any Camclosure integrated camera system under fluorescent lighting conditions.
REVISION HISTORY Manual # C2462M C2462M-A C2462M-B C2462M-C Date 11/02 1/03 10/05 1/06 C2462M-D C2462M-E 3/08 3/09 Comments Original version. Added Regulatory Notices for FCC Class B. Revised switch-setting descriptions for varifocal lens. Added WEEE statement. Updated factory switch settings for varifocal lens per ECO 13164. Updated wiring information. Added information about dome bubble. Revised for standard resolution color cameras with fixed focal lenses.
PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
www.pelco.com Pelco, Inc.