Off Grid Installation Manual
INSTALLATION MANUAL GUIDE | DATE: 02/2017
5
d.2) Mounting using "Clipping method" and profile insert
The solar modules are suitable for installation both with their long side up and
their short side up. Each module must be securely fastened at a minimum of 4
points on two opposite sides.
When installing inter-modules or end type clamps, take measures so as:
Not to bend the module frame;
Not to touch or cast shadow on the front glass;
Not to damage the surface of the frame;
To ensure the clamps overlap the module frame by at least 5 mm;
To ensure the clamps overlap length is at least 50 mm.
Clamp material should be anodized aluminum alloy.
Clamp positions are of crucial importance for the reliability of the installation, the
clamp centerlines must only be positioned within the clamping area indicated in
table.
For configurations where the mounting rails run parallel to the clamps installation
side, precautions should be taken to ensure the module frame (C-shape) overlap
the rail by 15 mm or more.