Installation to Wood Stud Wall
NOTE: This step is for mounting enclosure assembly (A) ush against supporting surface. For use with
mount, follow instructions provided with wall mount.
Use a stud nder to locate the edges of the studs and draw a vertical line down each stud’s center. Place
enclosure assembly (A) on wall as a template, level and mark the center of the six mounting holes. Make sure
that the mounting holes are on the stud centerlines. Drill six 5/32" (4 mm) dia. holes 2.5" (64 mm) deep. Make
sure that the enclosure is level and secure it using six 2.5" wood screws (C) and six washers (E) as shown in
gure 3.1.
NOTE: If cord cover plate assembly (K) is used on the rear of the enclosure, you may use the 1/2" spacer (M)
between enclosure assembly and wall surface.
DO NOT lift more weight than you can handle. Always use an assistant or mechanical lifting equipment to safely lift
and position enclosure assembly (A).
Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
Tighten wood screws so that the enclosure assembly is rmly attached, but do not overtighten. Overtightening can
damage the screws, greatly reducing their holding power.
Never tighten in excess of 80 in. • lbs. (9 N.M.).
Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud nder
is highly recommended.
Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs.
Installers are responsible to provide hardware for other types of mounting situations.