manual

15 of 50
ISSUED: 07-12-10 SHEET #: 061-9056-8 03-05-13
Locking Environmental Enclosure
Gently lower bay door. Using key (G) rotate door locks clockwise until key cannot turn. Make sure that the key has
fully rotated to seal enclosure. If key does not fully rotate, door lock may need to be adjusted for a looser seal. See
step 9-1 below for door lock adjustment.
NOTE: Gasket seal of bay door must be fully compressed to allow for a water tight seal. Test seal of door by
inserting a sheet of paper in between the door seal and the enclsosure seal. If the sheet of paper is easily removed,
door lock may need to be adjusted for a tighter seal. See step 9-1 below for door lock adjustment.
9
G
To allow for a tighter seal, loosen top nut of door locks 1/4" then tighten bottom nut of door locks against lock tab.
To allow for a more loose seal, loosen bottom nut of door locks 1/4" then tighten top nut of door locks against lock
tab.
Door Lock Adjustment
9-1
FRONT OF BAY DOOR
TOP NUT BOTTOM NUT
NUMBER OF LOCKS
ON DOOR MAY VARY
FROM ILLUSTRATION
Be careful not to pinch your ngers when opening and
closing bay door.
CAUTION