Installation Manual

Visit the Peerless Web Site at www.peerlessmounts.com
3 of 3
Installation to a concrete or cinder block wall
Drill four 1/4" (6 mm) dia. holes to a minimum depth of
2.5" (64 mm). Attach wall plate (A) using four concrete
anchors (C) and four #14 x 2 -1/2" wood screws (B) as
shown in Illustration A and 1, 2, and 3. Tighten all
fasteners.
3
Tighten wood screws firmly, but do not overtighten.
Overtightening can damage the screws, greatly
reducing their holding power.
Never tighten in excess of 80 in • lb (9 N.M.).
WARNING
Concrete anchors are not intended for attachment to
concrete wall covered with a layer of plaster, drywall,
or other finishing material. If mounting to concrete
wall covered with plaster/drywall is unavoidable,
plaster/drywall (up to 5/8" thick) must be
counterbored as shown right. If plaster/drywall is
thicker than 5/8", custom fasteners must be supplied
by installer.
WARNING
WARNING
When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual con-
crete surface in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a
solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90
specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a
hammer drill to avoid breaking out the back of the hole when entering a void or cavity.
Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
Make sure that the wall will safely support four times the combined load of the equipment and all attached
hardware and components.
B
C
Illustration A
A
ISSUED: 03-23-09 SHEET #:055-9262-1
1
3
2
Tighten all fasteners.
concrete
surface
C
UTAWAY VIEW
INCORRECT CORRECT
wall
plate
wall
plate
plaster/
dry wall
plaster/
dry wall
concrete
concrete
Drill holes and insert anchors
Place wall plate over anchors and secure with screws
B
B
A
C
C
C