User Guide
Programming Time & Temperature Settings
Your thermostat’s programming feature allows you to divide up a 24-hour day into four time
periods (referred to as “Wake”, “Day”, “Evening”, and “Sleep”), and give each time period its
own setpoint temperatures. Your “Heat Setpoint temperature” tells your heating system the room
temperature to maintain during cold weather. The “Cool Setpoint Temperature” tells your cooling
system the room temperature to maintain during hot weather.
Factory Program
Your thermostat comes from the factory preprogrammed with all seven days of the
week set to the times and temperatures shown below.
Time Period Start Time Heat Setpoint
Temperature
Cool Setpoint
Temperature
Wake 6:00 am 70° F (21.0° C) 78° F (25.5° C)
Day 8:00 am 62° F (16.5° C) 85° F (29.5° C)
Evening 6:00 pm 70° F (21.0° C) 78° F (25.5° C)
Sleep 10:00 pm 62° F (16.5° C) 72° F (22.0° C)
If the factory program meets your needs, simply follow the “Setting the Clock & Day”
instructions, and you’re done. If you want to change the preprogrammed times and/or
temperatures, follow the instructions under “Custom Program”.