User Manual
Specifications
INPUT SENSITIVITY:
Mic In to full power at the power amp. Master Volume Nom. 
  Full  Nominal
  -40 dBu  -22 dBu
Line In to full power at the power amp. Master Volume Nom. 
  Full  Nominal
  -10 dBu  +8 dBu
CHANNEL EQ:
Shelving EQ
  Low EQ  80 Hz  ±15 dB
  Mid-Morph
  Low  250 Hz  ±15 dB
  High  4 kHz  ±15 dB
  High EQ  12 kHz  ±15 dB
CLIP LED:
Clip LEDs come on 3 dB before clipping.
FREQUENCY RESPONSE:
All controls nominal (detent)
  Mic to Main  20 Hz – 20 kHz +0, -1 dB
  Line to Main  20 Hz – 30 kHz  +0, -1 dB
  Mic to Amp  50 Hz – 20 kHz  +0, -3 dB
  Line to Amp  40 Hz – 20 kHz  +0, -3 dB
PHANTOM POWER:
  +48 VOLTS
NOISE:
Main = Main line output, 22 – 22 kHz filter
Amp 1 = Amplifier output, loaded at 4 Ohms, through AP   
AUX-0025 switching amplifier filter
  All controls full down.
  Main  <-95 dBu
  Amp 1  <-60 dBu
  Master Volume nominal 
  Main  <-88 dBu
  Amp 1  <-55 dBu
THD:
All controls nominal 
 <0.01% @ main line output, -30 dBu in mic input Channel 1
  <0.5% @ amp 1 @ 400 Watts into 4 Ohms
All controls nominal 
  <0.005% @ main line output, +4 dBu in line input Channel 1
 <0.5% @ amp 1 @ 400 Watts into 4 Ohms
MASTER EQ:
  80Hz  ±12 dB
  250Hz  ±12 dB
  500Hz  ±12 dB
  1kHz  ±12 dB
  2kHz  ±12 dB
  4kHz  ±12 dB
  10kHz  ±12 dB
METER ARRAY:
  LIMIT
  -6 dB
  -12 dB
  -18 dB
  -24 dB
  -30 dB
AMP LIMITER:
Limits amplifier power just before clipping. The limiter holds the amp 
power without clipping and can be driven up to 18 dB past maximum 
output.
AMPLIFIER OUTPUT POWER:
120VAC
  Both channels loaded at 8 ohms:  280 Watts RMS per ch
  Both channels loaded at 4 ohms:  500 Watts RMS per ch
POWER REQUIREMENTS:
  Domestic:  120VAC 50/60Hz  200 Watts Nominal
  Export:  230VAC 50/60Hz  200 Watts 
Nominal 
SIZE: 
Dimensions:  H x W x D
    9.5" x 19" x 9.5"
    24.13cm x 48.26cm x 24.13cm
WEIGHT:    16 lbs.
    7.25 kgs 
Features and specifications subject to change without notice.
Peavey Electronics Corporation • 5022 Hartley Peavey Drive • Meridian, MS • 39305
(601) 483-5365 • FAX (601) 486-1278 • www.peavey.com • 31700107 • ©2015
Logo referenced in Directive 2002/96/EC Annex IV
(OJ(L)37/38,13.02.03 and defined in EN 50419: 2005
The bar is the symbol for marking of new waste and 
is applied only to equipment manufactured after
13 August 2005