Use and Care Manual

9
To ensure proper ignition make sure the igniter pin is properly
positioned and connected.
- The igniter pin should be pointed straight to the thermocouple.
- The thermocouple should be positioned 5mm away from the burner tube.
Make sure that the pilot housing is unobstructed.
Clear any debris on top of the pilot housing and make sure there is no debris between the
igniter pin, thermocouple and the burner tube.
Helpful Tips
If the burner will not light or stay lit,
please perform the following checks.
Turn the control knob to o and close the LP Gas tank valve. Disconnect the regulator. Turn
the Control Knob to “HIGH”. Wait a minimum of 5 minutes. Turn burner control knob back to
“OFF”. Reconnect the regulator and perform a leak check at tank connection. Turn the LP Gas
tank valve on slowly, wait 30 seconds and then light the outdoor fire table.
It is possible that the Excess Flow Safety Device has been tripped.
Make sure the
wires are fully
inserted into
the ignitor box.
If wires are too
close, or tangled,
they could short.
Make sure they
are spaced apart
from each other.