User Manual

9. Integrated storage battery:
The integrated storage battery serves to backup the
measured values in case of power failure or when
the unit is unplugged from the outlet
When the unit is connected to the electrical grid, the
storage battery reloads itself automatically
The storage battery is integral and hasn’t to be
replaced or disposed separately
10. Technical Specification
Nominal input voltage 230V AC; 50Hz
Voltage measurement 200 - 276 V AC,
45 - 65Hz
Maximum load 16A, 3680W
Lower current range 0.005A
Power consumption <0.5W
Current display 0.005A ... 16.000A
Watt Range 0.0 ... 3680.0 W
Power factor calculation 0.10 ... 1.00
Consumption display 0.0 ... 9999.9 kWh
Accuracy + / - 0.5%
Operation temperature +10°C … +40°C;
<75%RH
Storage temperature 0°C … 50°C;
<75%RH
Internal Battery Ni-Mh 3.6V
Dimensions (WxHxD) 120 x 60 x 75 mm
Weight 160g
-47-