9. Integrated storage battery: 
  The integrated storage battery serves to backup the 
measured  values  in  case  of  power  failure  or  when 
the unit is unplugged from the outlet 
  When the unit is connected to the electrical grid, the 
storage battery reloads itself automatically 
  The  storage  battery  is  integral  and  hasn’t  to  be 
replaced or disposed separately 
10. Technical Specification 
Nominal input voltage  230V AC; 50Hz 
Voltage measurement   200 - 276 V AC, 
      45 - 65Hz 
Maximum load     16A, 3680W 
Lower current range    0.005A 
Power consumption    <0.5W 
Current display     0.005A ... 16.000A 
Watt Range    0.0 ... 3680.0 W 
Power factor calculation   0.10 ... 1.00 
Consumption display    0.0 ... 9999.9 kWh 
Accuracy      + / - 0.5% 
Operation temperature   +10°C … +40°C;  
      <75%RH 
Storage temperature    0°C … 50°C; 
      <75%RH 
Internal Battery    Ni-Mh 3.6V 
Dimensions (WxHxD)    120 x 60 x 75 mm 
Weight      160g 
-47- 