User Manual

7. Overload settings
With a preset overload an OVERLOAD symbol flashes
on the display when the set value is exceeded. This
value is normally set to 16A.
Press the MODE button for about 5 seconds in the
voltage measurement, current measurement and
power measurement menu to activate the overload
settings.
Press the MODE button twice to switch from
PRICE1 and PRICE2 to the OVERLOAD settings.
Press the SET button. The first digit (tens of
amperes) starts to flash.
Press the key to change this value.
Press the SET button again to select the second
digit (one amp).
Press the key to change this value.
Press the SET button again to select the third digit
(0.1 amps).
Press the key to change this value.
Press the SET button again to select the fourth digit
(0.01 amps).
Press the key to change this value.
Confirm with the SET key
-37-