Datasheet

8 GND Terminal () Green colour
Chassis ground terminal, normally this is to be short to (+) or (-)
as required by user.
9. Output Terminal Negative (-) Black colour
10. LCD Display panel showing 4 digit voltage, current meter,
(CV) constant voltage mode, (CC) constant current mode,
Output Terminal on/off state
5. OPERATIONS
Ground Connection
Depending on the application, the power supply output terminals can
be grounded in any one of the following grounding conditions:
Negative ground - black (-) negative terminal is shorted with green
GND terminal.
Positive ground - red (+) positive terminal is shorted with green GND
terminal.
Floating ground - green terminal is not shorted with any of the output
terminals.
Remarks :
When operating this power supply as a floating ground, high
impedance leakage can exist between the power supply circuitry and
the chassis ground.
-17-
9. Negative (-) Ausgangsbuchse (Schwarz)
10. LCD Display mit vierstelliger Darstellung der
Spannungsanzeige, Stromanzeige, (CV) constant voltage
(Konstantspannung), (CC) constant current (Konstantstrom),
Ausgangsbuchsen on/off (Ein/AUS) Status
5. Funktionen
Erdungsanschluss
Abhängig von der Verwendung des Netzgerätes, können die
Ausgangsbuchsen in jeder der folgenden Möglichkeiten geerdet
werden:
Negative Masse - Schwarze (-) negative Buchse wird mit der
Erdungsbuchse (Grün) kurzgeschlossen.
Positive Masse - Rote (+) positive Buchse wird mit der
Erdungsbuchse (Grün) kurzgeschlossen. .
Potentialfreie Erdung Die grüne PE-Buchse wird mit keiner anderen
Ausgangsbuchse kurzgeschlossen.
Anmerkungen:
Durch die Benutzung mit potentialfreier Erdung kann es zu einem
Potentialunterschied zwischen dem Gehäuse und den inneren
Schaltkreisen der Spannungsversorgung kommen.
-6-