Datasheet

* To avoid electrical shock, do not operate this product in wet or
damp conditions. Conduct measuring works only in dry clothing
and rubber shoes, i. e. on isolating mats
Never touch the tips of the test leads or probe
Comply with warning labels and other info on the equipment
* Do not subject the equipment to direct sunlight or extreme
temperatures, humidity or dampness
Do not subject the equipment to shocks or strong vibrations
* Do not operate the equipment near strong magnetic fields
(motors, transformers etc.)
Keep hot soldering irons or guns away from the equipment
* Allow the equipment to stabilise at room temperature before
taking up measurement important for exact measurements)
* Periodically wipe the cabinet with a damp cloth and mid
detergent. Do not use abrasives or solvents
The meter is for indoor use only.
* Do not operate the meter before the cabinet has been closed and
screwed safely as terminal can carry voltage.
* Do not store the meter in a place of explosive, inflammable
substances.
Do not modify the equipment in any way
* Opening the equipment and service- and repair work must only
be performed by qualified service personnel
* The instrument must be set up so that the power plug can
removed from the socket easily.
Measuring instruments don’t belong to children hands
Cleaning the cabinet
Prior to cleaning the cabinet, withdraw the mains plug from the power
outlet.
Clean only with a damp, soft cloth and a commercially available mild
household cleanser. Ensure that no water gets inside the equipment
to prevent possible shorts and damage to the equipment.
Keep this manual in a safe place for quick reference at all times.
-13-
7. Technische Daten
Eingangsspannung(umschaltbar) 200 - 240V AC , 50/60Hz
Max. Eingangsstrom bei 230V AC 0.83A
Ausgangsspannung 1.0 - 20V DC (P 6095); 1.0 - 36V DC (P 6135)
Ausgangsstrom 0 - 5A (P 6095) ; 0 - 3A (P 6135)
Spannungsregulierung- Abweichungen:
bei 10% bis 100% Last 70mV
bei Netzspannung von 180 bis 264V AC 20mV
Restwelligkeit in r.m.s. 5mV
Restwelligkeit (Peak to Peak) 30mV
Stromregulierung - Abweichungen:
bei 10% bis 100% Last 20mA
bei Netzspannung von 180 bis 264V AC 20mA
Restwelligkeit (peak to peak) 20mA
Schaltfrequenzen 80KHz to 120KHz
Leistungsfaktor 0.68
Effizienz der Ausgangsleistung 84%
Potentiometerbauform Drahtgewickelt
Spannungs- und Stromanzeige 4 Digit
Voltmeter Genauigkeit ±1% +5 counts for range V<5V
±1%+3 counts for range V>5V
Amperemeter Genauigkeit
±1% +5 counts for range I<2A
±1% +3 counts for range I>2A
LCD Anzeige
CC, CV, Amp, Volt, Output ON-OFF
Schutzeinrichtungen
Kurzschluss, Überlast, Überhitzung,
Fehlfunktion OVP
CE Normen
LVD : EN 61010 , EMC : EN 55011
Kühlsystem
Passiv
Maße in mm (BxHxT)
70 x 150 x 250mm
Gewicht
2 Kg
Anmerkungen
Daten basieren auf Messungen bei 230V 50Hz
-10-